Feasibility of Laparoendoscopic Single-Site Partial Nephrectomy in a Porcine Model

نویسندگان

  • Dong-Hun Koo
  • Yong Hyun Park
  • Chang Wook Jeong
  • Hyeon Jeong
  • Hyeon Hoe Kim
  • Seung Bae Lee
چکیده

PURPOSE We performed laparoendoscopic single-site (LESS) partial nephrectomy in a porcine model with the objectives of overcoming the technical challenges of this surgery and exploring its feasibility. MATERIALS AND METHODS Six partial nephrectomies were performed on a pig aged 5 months, three cases on each kidney, by four surgeons: two urologists with much experience in laparoscopic surgery (E1, E2) and two less-experienced urologists (B1, B2). While under general anesthesia, the swine was placed in a lateral flank position. Umbilical placement of an Octoport was done with a 2.5 cm incision. After dissection of the renal hilum and Gerota's fascia, a bulldog clamp was applied on the renal artery and parenchymal resection was done. Renorrhaphy was then performed with interrupted sutures with the use of a sliding knot technique. RESULTS All six partial nephrectomies were performed successfully after repair of the vascular and collecting system at the resection margin and renorrhaphy without the need to introduce any additional ports. There were no noticeable intra- or postoperative complications. The mean warm ischemic time was 42 minutes (range, 30-60 minutes). The shortest warm ischemic time, 30 minutes, was achieved by using the early unclamping technique during renorrhaphy. The longest warm ischemic time was 60 minutes. The average number of renorrhaphy stitches was 3.2 (range, 2-5). CONCLUSIONS LESS partial nephrectomy was successfully performed in a porcine model but resulted in a longer ischemic time than that of conventional laparoscopic surgeries. Therefore, further laboratory disciplinary efforts are needed to decrease the warm ischemic time and to improve this surgical technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Robot-Assisted Laparoendoscopic Single-Site Partial Nephrectomy and Standard Radical Prostatectomy

Recently, patients with urologic malignancies are treated with robot-assisted surgery and the expanded role of robot-assisted surgery includes even those patients with two concomitant primary urologic malignancies. In an effort to further reduce port site-related morbidity, robot-assisted laparoendoscopic single-site surgery (RLESS) has been developed. Therefore, we present herein our early exp...

متن کامل

A novel approach to locate renal artery during retroperitoneal laparoendoscopic single-site radical nephrectomy.

OBJECTIVE To verify the feasibility and safety of retroperitoneal laparoendoscopic single-site radical nephrectomy and assess the value of our proposed approach to search for renal artery. METHODS A total of 60 cases of retroperitoneal laparoendoscopic single-site radical nephrectomy were performed using our homemade single-port multi-channel device. An incision of 5-6 cm was cut forward from...

متن کامل

Laparoendoscopic Single-Site Surgeries: A Single-Center Experience of 171 Consecutive Cases

PURPOSE We report our experience to date with 171 patients who underwent laparoendoscopic single-site surgery for diverse urologic diseases in a single institution. MATERIALS AND METHODS Between December 2008 and August 2010, we performed 171 consecutive laparoendoscopic single-site surgeries. These included simple nephrectomy (n=18; robotic surgeries, n=1), radical nephrectomy (n=26; robotic...

متن کامل

Multicenter Experience with Nonischemic Multiport Laparoscopic and Laparoendoscopic Single-Site Partial Nephrectomy Utilizing Bipolar Radiofrequency Ablation Coagulator

Objective. To investigate feasibility of multiport and laparoendoscopic single-site (LESS) nonischemic laparoscopic partial nephrectomy (NI-LPN) utilizing bipolar radiofrequency coagulator. Methods. Multicenter retrospective review of 60 patients (46 multiport/14 LESS) undergoing NI-LPN between 4/2006 and 9/2009. Multiport and LESS NI-LPN utilized Habib 4X bipolar radiofrequency coagulator to f...

متن کامل

Laparoendoscopic Single-Site Surgery With the Second-Generation Single Port Instrument Delivery Extended Reach Surgical System in a Porcine Model

PURPOSE To describe our initial experience with the second-generation Single Port Instrument Delivery Extended Reach (SPIDER) laparoendoscopic single-site surgical system in a porcine model. MATERIALS AND METHODS In four swine weighing approximately 32 to 35 kg, five nephrectomies, four adrenalectomies, three pyeloplasties, and three partial cystectomies and closures were performed by a singl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2011