A Wavelet-Based Processing method for simultaneously determining ultrasonic velocity and material thickness.
نویسندگان
چکیده
Methods of measuring ultrasonic wave velocity in an elastic sample require data on the thickness of the sample and/or the distances between the transducers and the sample. The uncertainty of the ultrasonic wave velocity measurements generally depends on that of the data available. Conversely, to determine the thickness of a material, it is necessary to have a priori information about the wave velocity. This problem is particularly hard to solve when measuring the parameters of biological specimens such as bones having a greater acoustical impedance contrast (typically 3-5 MRayl) than that of the surrounding soft tissues (typically 1.5 MRayl). Measurements of this kind cannot easily be performed. But obtaining the thickness of a bone structure and/or the ultrasonic wave velocity is a important problem, for example, in biomechanical field for the calculation of elastic modulus, or in acoustical imaging field to parameterize the images, and to reference the grey or color level set to a physical parameter. The aim of the present study was to develop a method of simultaneously and independently determining the velocity of an ultrasonic wave in an elastic sample and the wave path across the thickness of this sample, using only one acquisition in pure transmission mode. The new method, which we have called the "Wavelet-Based Processing" method, is based on the wavelet decomposition of the signals and on a suitable transmitted incident wave correlated with the experimental device, and the mathematical properties such as orthonormality, of which lend themselves well to the time-scale approach. By following an adapted algorithm, ultrasonic wave velocities in parallelepipedic plates of elastic manufactured material and the apparent thicknesses were both measured using a water tank, a mechanical device and a matched pair of 1MHz ultrasonic focused transducers having a diameter of 3mm, a focal length of 150mm and beam width of 2×2mm at the focus (mean temperature 22°). The results were compared with those obtained with a conventional Pulse-mode method and with the control values, to check their validity. Measurements performed on bovine and human dry cortical bone samples are also presented to assess the limitations of the method when it is applied to elastic biological samples, including those of an equal-wavelength size (≈1.5mm). The thicknesses and the ultrasonic wave velocities were then measured in this kind of (quasi-) parallelepipedic elastic materials with an mean estimated error ranged from 1% to 3.5% compared to the referenced values.
منابع مشابه
Thin bone sample assessment using ultrasonic transmitted signals based on wavelet processing method
The wavelet-based processing (WBP) method based on Meyer-Jaffard algorithm was implemented to simultaneously determine the thickness and velocity of thin cortical bone samples. Two groups of bovine samples were measured by one pair of immersion transducers with nominal frequency 2.25MHz. The WBP method was used to estimate the times of flight (TOF) of two pulses contained by one transmitted sig...
متن کاملNondestructive Maturity Determination of Durian by Force Vibration and Ultrasonic
The nondestructive determination of the maturity of durian is an important process for quality control. Since durian has specific properties, such as the thickness of peel, non-uniformity of shape, roughness of prickle skin, largeness of size etc., the nondestructive determination of the maturity is hard to perform. This paper proposes two approaches for determining maturity of durian by using ...
متن کاملIn situ Simultaneous Measurement of Temperature and Thin Film Thickness with Ultrasonic Techniques
A novel technique to measure in situ, simultaneously, temperature and thin film thickness during semiconductor processing is described in this paper. The measurement technique is based on the principle propagating in a silicon wafer is a function of both the that the velocity of an ultrasonic Lamb wave wafer temperature and the thin film coating on the wafer surface. We are able to btain the pr...
متن کاملFUZZY EVALUATION SYSREM OF VELOCITY AND THICKNESS BY MULTI-DIRECTION ULTRASONIC PROBE JUN YASUI, GRADUATE SCHOOL OF ENGINEERING, UNIVERSITY OF HYOGO, JAPAN, [email protected] SYOJI KOBASHI, GRADUATE SCHOOL OF ENGINEERING, UNIVERSITY OF HYOGO, JAPAN, [email protected]
Development of an ultrasonic device to image the hardness of tissues is important for a cancer diagnosis. Conventional methods cannot precisely measure the size of object, because the sound speed of an object is unknown. We propose a fuzzy inference system for ultrasonic imaging based on the velocity of materials. This method consists of three stages. In the first stage, the surface of the obje...
متن کاملMonitoring Pipe-Wall Corrosion Rate by Ultrasonic Technique
thickness and corrosion/erosion rate. In this thesis, a combination of signal processing techniques are used to estimate the corrosion rate estimates based on MBE. Corrosion rate is estimated based on ultrasonic pipe wall thickness data is collected over a short period of time using MBE model. This technique is based on data collected from the speedometer applied for thinning and both indicate ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonics
دوره 51 3 شماره
صفحات -
تاریخ انتشار 2011