Reproducibility of peripapillary retinal nerve fiber layer thickness measurements using spectral domain OCT in Brazilian patients.

نویسندگان

  • Daniela Araújo Toscano
  • Marcos Pereira de Ávila
  • Maria Regina Catai Chalita
چکیده

PURPOSE To evaluate the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements in normal eyes and eyes with glaucoma using spectral domain optical coherence tomography (SDOCT). METHODS One eye of 79 normal and 72 glaucoma patients was analyzed. All patients underwent a complete ophthalmological examination, including visual acuity testing; intraocular pressure, slit-lamp examination, indirect ophthalmoscopy; and the glaucoma group underwent achromatic perimetry with the 24-2 SITA Fast Humphrey Field Analyzer. All patients' eyes were scanned using the spectral domain optical coherence tomography - Spectralis(®) and one of them was chosen randomly. Three consecutive circular B-scan centered at the optic disc were performed in one visit. RESULTS The intraclass correlation coefficient (ICC), coefficient of variation and test-retest variability for the mean retinal nerve fiber layer thickness were respectively: 0.94, 2.56% and 4.85 µm for the normal group and 0.93, 4.65% and 6.61 µm for the glaucomatous group. The intraclass correlation coefficient for retinal nerve fiber layer thickness in all quadrants were all excellent in both groups, with the superior quadrant having the highest ICCs (0.964) in glaucomatous eyes and nasal quadrant measurements having the lowest (0.800), but still excellent in eyes without glaucoma. The coefficient of variation was between 2.56% - 8.74% and between 4.65% - 11.44% in normal and glaucomatous group respectively. The test-retest variability was between 4.85 µm and 11.51 µm in the normal group and between 6.61 µm and 14.24 µm in the glaucomatous group. The measurements in glaucomatous eyes were more variable than normal eyes. CONCLUSIONS Spectral domain optical coherence tomography showed excellent reproducibility with regard to retinal nerve fiber layer thickness measurements in normal and glaucomatous eyes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of retinal nerve fiber layer thickness measurements using spectral domain optical coherence tomography.

PURPOSE To evaluate the reproducibility of the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained by Spectralis spectral domain optical coherence tomography (OCT) (Heidelberg Engineering, Heidelberg, Germany) in normal and glaucoma participants. METHODS Participants were recruited from a university-based clinic. Peripapillary RNFL thickness measurements were repeat...

متن کامل

Agreement of Two Different Spectral Domain Optical Coherence Tomography Instruments for Retinal Nerve Fiber Layer Measurements

PURPOSE To determine the agreement between Spectralis and Cirrus spectral domain optical coherence tomography (SD-OCT) measurements of peripapillary retinal nerve fiber layer (RNFL) thickness. METHODS Suspected or confirmed cases of glaucoma who met the inclusion criteria underwent peripapillary RNFL thickness measurement using both the Spectralis and Cirrus on the same day within a few minut...

متن کامل

Intrasession reproducibility of RNFL thickness measurements using SD-OCT in eyes with keratoconus.

BACKGROUND AND OBJECTIVE To evaluate the intrasession reproducibility of the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained by spectral-domain optical coherence tomography (SD-OCT) in eyes with keratoconus and normal eyes. PATIENTS AND METHODS Peripapillary RNFL thickness measurements with SD-OCT were repeated three times during the same visit using the eye tra...

متن کامل

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

PURPOSE To compare the peripapillary retinal nerve fiber layer (RNFL) thickness of normal patients and those with various glaucoma diseases by time domain (Stratus) and spectral domain (Spectralis) optical coherence tomography (OCT). METHODS The RNFL thickness as measured by the Stratus and Spectral OCT was compared (paired t-test). The relationship and agreement of RNFL thickness between the...

متن کامل

Evaluation of Retinal Nerve Fiber Layer Thickness in Retinitis Pigmentosa Patients Using Spectral-Domain OCT

Purpose To measure the peripapillary retinal nerve fiber layer (RNFL) thickness using spectraldomain OCT (SD-OCT) in patients with retinitis pigmentosa. Methods Fifty eyes of 30 patients with retinitis pigmentosa underwent a complete ocular examination, including best-corrected visual acuity (BCVA) using a Snellen chart, slit-lamp biomicroscopic examination, and Goldmann applanation intraocular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 75 5  شماره 

صفحات  -

تاریخ انتشار 2012