Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure.

نویسندگان

  • M Nogler
  • M Krismer
  • C Haid
  • M Ogon
  • C Bach
  • C Wimmer
چکیده

The ROBODOC system is a promising new method for removing cement with high-speed milling. Heat is generated during the milling process. This study was designed to measure temperatures in the cutting area, and to assess the risk of heat injury and the effectiveness of irrigation. We measured temperatures at the bone-cement cutting area in three experimental settings, two involving the proximal area comprising a cement mantle, and one the distal cement plug beneath the prosthesis. Without cooling facilities, a mean temperature of 94 degrees C was measured in proximal areas. However, this could effectively be reduced below 70 degrees C with irrigation. In the area of the distal cement plug, we measured a mean temperature of 172 degrees C without irrigation. In this area, the integrated irrigation system with an additional high-flow irrigation system could not guarantee cooling to an acceptable temperature of below 70 degrees C since the irrigation stream was impeded by the cutter in the narrow cavity. We need an integrated irrigation device that guarantees continuous cooling at the cutting interface in front of the cutter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cement Removal from the Femur Using the ROBODOC System in Revision Total Hip Arthroplasty

Introduction. The perforation and fracture of the femur during the removal of bone cement in revision total hip arthroplasty (THA) are serious complications. The ROBODOC system has been designed to selectively remove bone cement from the femoral canal, but results have not been reported yet. The purpose of our study was to evaluate the clinical and radiographic results of revision THA using the...

متن کامل

Computer-integrated revision total hip replacement surgery: concept and preliminary results

This paper describes an ongoing project to develop a computer-integrated system to assist surgeons in revision total hip replacement (RTHR) surgery. In RTHR surgery, a failing orthopedic hip implant, typically cemented, is replaced with a new one by removing the old implant, removing the cement and fitting a new implant into an enlarged canal broached in the femur. RTHR surgery is a difficult p...

متن کامل

Revision of the cemented femoral stem using a cement-in-cement technique: a five- to 15-year review.

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The st...

متن کامل

Primary and revision total hip replacement using the Robodoc system.

The ROBODOC system was designed to address potential human errors in performing cementless total hip replacement. The system consists of a preoperative planning computer workstation (called ORTHODOC) and a five-axis robotic arm with a high speed milling device as an end effector. The combined experience of the United States Food and Drug Administration multicenter trial and the German postmarke...

متن کامل

Cement-in-cement acetabular revision with a constrained tripolar component.

Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Scandinavica

دوره 72 6  شماره 

صفحات  -

تاریخ انتشار 2001