Electromagnetic head-and-neck hyperthermia applicator: experimental phantom verification and FDTD model.

نویسندگان

  • Margarethus M Paulides
  • Jurriaan F Bakker
  • Gerard C van Rhoon
چکیده

PURPOSE To experimentally verify the feasibility of focused heating in the neck region by an array of two rings of six electromagnetic antennas. We also measured the dynamic specific absorption rate (SAR) steering possibilities of this setup and compared these SAR patterns to simulations. METHODS AND MATERIALS Using a specially constructed laboratory prototype head-and-neck applicator, including a neck-mimicking cylindrical muscle phantom, we performed SAR measurements by electric field, Schottky-diode sheet measurements and, using the power-pulse technique, by fiberoptic thermometry and infrared thermography. Using phase steering, we also steered the SAR distribution in radial and axial directions. All measured distributions were compared with the predictions by a finite-difference time-domain-based electromagnetic simulator. RESULTS A central 50% iso-SAR focus of 35 +/- 3 mm in diameter and about 100 +/- 15 mm in length was obtained for all investigated settings. Furthermore, this SAR focus could be steered toward the desired location in the radial and axial directions with an accuracy of approximately 5 mm. The SAR distributions as measured by all three experimental methods were well predicted by the simulations. CONCLUSION The results of our study have shown that focused heating in the neck is feasible and that this focus can be effectively steered in the radial and axial directions. For quality assurance measurements, we believe that the Schottky-diode sheet provides the best compromise among effort, speed, and accuracy, although a more specific and improved design is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a new hyperthermia application for treatment of head and neck tumors : a theoretical exploration

In this thesis a theoretical investigation to a new head and neck hyperthermia applicator is described. This project forms the first step towards the development of a head and neck hyperthermia treatment system. Hyperthermia is defined as a temperature elevation by several degrees (3-TC) above the normal physiological level. A hyperthermia cancer treatment aims to kill cancerous cells by delibe...

متن کامل

MASTER Development of a new hyperthermia application for treatment of head and neck tumors : a theoretical exploration

In this thesis a theoretical investigation to a new head and neck hyperthermia applicator is described. This project forms the first step towards the development of a head and neck hyperthermia treatment system. Hyperthermia is defined as a temperature elevation by several degrees (3-TC) above the normal physiological level. A hyperthermia cancer treatment aims to kill cancerous cells by delibe...

متن کامل

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the tre...

متن کامل

Assessment of the local SAR distortion by major anatomical structures in a cylindrical neck phantom.

The objective of this work is to gain insight in the distortions on the local SAR distribution by various major anatomical structures in the neck. High resolution 3D FDTD calculations based on a variable grid are made for a semi-3D generic phantom based on average dimensions obtained from CT-derived human data and in which simplified structures representing trachea, cartilage, spine and spinal ...

متن کامل

Hyperthermia Applicator for Electromagnetic interaction with Human tissue at 434 MHz

Hyperthermia is the most recent therapy in investigating the biological effects and applications of microwaves for treatment of cancer and tumour. It refers to an artificial heating above 45°C in order to cure cancer. Various antennas like slot antenna, loop antenna, dipole antenna and patch antenna etc. are used as Hyperthermia applicators for damaging and killing cancerous cells from the body...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 2007