The efficacy of antigen-specific immunoadsorption and rebound of anti-A/B antibodies in ABO-incompatible kidney transplantation.
نویسندگان
چکیده
BACKGROUND As antigen-specific immunoadsorption (IA) using the Glycosorb®-ABO columns is becoming increasingly popular in ABO-incompatible (ABOi) transplantation, in this study, we retrospectively investigated the efficacy of Glycosorb®-ABO IA in vivo and ex vivo. We also assessed the risk of anti-A/B antibody (ABab) rebound before and after ABOi kidney transplantation. METHODS A protocol for ABOi living donor kidney transplantation was used, combining four preoperative and three preemptive postoperative Glycosorb®-ABO IAs with rituximab and maintenance immunosuppression. ABabs were determined by a haemagglutination titration technique. RESULTS ABOi kidney transplantation was attempted 45 times and 43 transplantations were performed. Overall patient survival was 93% and graft survival was 91%. Mean follow-up was 4.5 years. Glycosorb®-ABO IA significantly reduced the ABabs in the majority of patients (P < 0.0001). However, in three patients (6.8%), the antibody elimination was incomplete. Inadequate adsorption of core-chain-dependent ABabs may explain this finding, but further studies are needed. In five patients, the preconditioning was interrupted before transplantation, resulting in ABab rebound. Yet, when preconditioning was restarted, the antibodies could be removed as planned. After ABOi transplantation, rebound of ABabs was seen in two patients (5%). CONCLUSIONS Glycosorb®-ABO IA in combination with rituximab effectively depletes ABabs in most patients, but owing to core-chain-dependent ABabs, Glycosorb®-ABO IA may be less effective than nonspecific techniques for antibody removal in some patients. Rebound before transplantation subsequent to interrupted preconditioning does not hamper a successful ABOi transplantation. Postoperatively, when this protocol for ABOi transplantation is followed, the risk of ABab rebound is small.
منابع مشابه
Implementation of a Protocol for ABO-incompatible kidney transplantation--a three-center experience with 60 consecutive transplantations.
BACKGROUND A new protocol for ABO-incompatible kidney transplantation has recently been introduced. We report here on the joint experience of the implementation in Stockholm and Uppsala, Sweden and Freiburg, Germany. METHODS The new protocol utilizes antigen-specific immunoadsorption to remove existing ABO-antibodies, rituximab, and intravenous immunoglobulin to prevent the rebound of antibod...
متن کاملTreatment of large plasma volumes using specific immunoadsorption to desensitize ABO-incompatible kidney-transplant candidates
BACKGROUND ABO-incompatible (ABOi) kidney-transplantation has very good long-term results, i.e. similar to those observed for living-kidney ABO-compatible transplantation. This is because patients are desensitized at pretransplant using apheresis and rituximab therapy, with tacrolimus-based immunosuppression. OBJECTIVES To assess the efficacy of a single, pretransplant (Day -1), specific immu...
متن کاملEfficacy and safety of tandem hemodialysis and immunoadsorption to desensitize kidney transplant candidates.
OBJECTIVES We conducted a desensitization program in our center in patients undergoing kidney transplant for end-stage renal disease. These patients had a living-donor either ABO incompatible and/or human-leukocyte antigen-incompatible. The safety and efficacy of this program were evaluated. MATERIALS AND METHODS A pretransplant desensitization program relies on immunosuppressants and apheres...
متن کاملABO-Incompatible Kidney Transplantation: Overview and New Strategies
The increasing shortage of human organs for transplantation has regained interest in blood group ABO-incompatible kidney transplantation, especially living donor kidney transplantation. After being performed at a few centers during the 1980s, ABO-incompatible renal transplantation has continued to expand over the years. More than 1000 ABO-incompatible living donor transplantations have been per...
متن کاملLate antibody-mediated rejection after ABO-incompatible kidney transplantation during Gram-negative sepsis
BACKGROUND The major challenge in ABO-incompatible transplantation is to minimize antibody-mediated rejection. Effective reduction of the anti-ABO blood group antibodies at the time of transplantation has made ABO-incompatible kidney transplantation a growing practice in our hospital and in centers worldwide. ABO antibodies result from contact with A- and B-like antigens in the intestines via n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2011