Cross-reactivity of nonspecific treponemal antibody in serologic tests for Lyme disease.
نویسندگان
چکیده
Serum samples obtained from 59 persons who had acute necrotizing ulcerative gingivitis, periodontitis, syphilis, or Lyme disease were tested against Treponema phagedenis biotype Reiter, Treponema denticola, Treponema vincentii, and Treponema scoliodontum by indirect fluorescent-antibody staining methods. Although there were positive reactions for sera representing each of these study groups and for 20 (13%) of 156 samples collected from the general population (premarital screening for syphilis), titration endpoints were relatively low (less than or equal to 1:256). Serum samples from 18 persons who had gingivitis or periodontitis but no history of Lyme borreliosis were tested by enzyme-linked immunosorbent assay for antibodies to Borrelia burgdorferi. Of these, five (28%) had immunoglobulin M antibody and four (22%) contained immunoglobulin G antibodies to this spirochete. Adsorption with either sorbent commercially prepared from T. phagedenis biotype Reiter or with washed, whole cells of T. phagedenis biotype Reiter reduced cross-reactivity in the enzyme-linked immunosorbent assay for Lyme borreliosis.
منابع مشابه
Cross-reactivity to Borrelia burgdorferi proteins in serum samples from residents of a tropical country nonendemic for Lyme disease.
Reports of Lyme disease from areas where the disease is not endemic have increased. Eighty-six human serum samples from Papua New Guinea (nonendemic for Lyme disease) were examined for the presence of IgG antibodies that recognize Borrelia burgdorferi antigens, using the currently recommended two-tiered system of analysis (sensitive ELISA with Western blot). The percentage of positive tests dro...
متن کاملBiological false positive serological tests for syphilis in the Jamaican population.
A total of 19,067 sera were screened for biological false positive (BFP) reactivity by the Venereal Disease Research Laboratory (VDRL) test. Sera which were reactive in the VDRL test were confirmed by the fluorescent treponemal antibody absorption (FTA-ABS) test. BFP reactions were detected in 0.59% of the general population, 0.72% of pregnant women and 11.8% of patients with systemic lupus ery...
متن کاملFalse-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.
Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals an...
متن کاملThe Borrelia burgdorferi 37-kilodalton immunoblot band (P37) used in serodiagnosis of early lyme disease is the flaA gene product.
The 37-kDa protein (P37) of Borrelia burgdorferi is an antigen that elicits an early immunoglobulin M (IgM) antibody response in Lyme disease patients. The P37 gene was cloned from a B. burgdorferi genomic library by screening with antibody from a Lyme disease patient who had developed a prominent humoral response to the P37 antigen. DNA sequence analysis of this clone revealed the identity of ...
متن کاملLatent syphilis: immunoglobulins reactive in immunofluorescence and other serological tests.
Study of sera from 69 patients with untreated or inadequately treated latent syphilis revealed that immunoglobulin (Ig)G antibodies made up the bulk of the fluorescent treponemal antibody-absorption (FTA-ABS)-test reactivity found in the sera. IgM and IgA antibodies also contributed in some cases. Venereal Disease Research Laboratory slide-test reactivity was found in both 19 and 7S serum fract...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 28 6 شماره
صفحات -
تاریخ انتشار 1990