Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis.
نویسندگان
چکیده
Extracellular volume (ECV) of arms, trunk, and legs determined from segmental bioimpedance data in 11 healthy men (31.6 +/- 7 yr) obtained at the end of a 30-min equilibration phase in the supine body position was compared with ECV determined from whole body measurements (ECVWB). ECV was calculated from extracellular resistance (RECV) identified from the bioimpedance spectrum for a range of 10 frequencies. Whole body RECV (527.6 +/- 55.6 Omega) was equal to the sum of RECV in the arms, trunk, and legs (241.6 +/- 36. 3, 49.2 +/- 5.1, and 236.3 +/- 25.5 Omega, respectively). The sum of equilibrated ECV in arms (1.31 +/- 0.25 liters), trunk (10.08 +/- 1.65 liters), and legs (2.80 +/- 0.82 liters) was smaller than ECVWB (20.90 +/- 2.59 liters). In six subjects who changed from a standing to a supine body position, ECV decreased in arms (-2.59 +/- 2.51%, P = NS) and legs (-10.96 +/- 3.02%, P < 0.05) but increased in the trunk (+4.2 +/- 3.2%, P < 0.05). ECVWB also decreased (-4.98 +/- 1. 41%, P < 0.05). However, the sum of segmental extracellular volumes remained unchanged (-0.06 +/- 0.07%, P = NS). The sum of segmental ECVs is not sensitive to changes in body position, which otherwise interferes with the estimation of ECV in bioimpedance analysis when ECVWB is used.
منابع مشابه
Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positi...
متن کاملEffect of change in fluid distribution in segments in hemodialysis patients at different ultrafiltration rates on accuracy of whole body bioimpedance measurement.
This study explored divergence (error) between ultrafiltration volumes (UFV) and intradialytic changes in extracellular volume (ΔECV) in hemodialysis (HD) patients measured by whole body (wBIS) and sum of segmental bioimpedance spectroscopy (sBIS). The primary aim of the study was to evaluate the effect of different ultrafiltration rates (UFR) on error of estimation of ΔECV by changes in their ...
متن کاملInfluence of body position, food and beverage consumption on BIS measurements
Continuous monitoring of fluid changes using bioimpedance spectroscopy (BIS) during hemodialysis could help to predict hypotensive complications and extend the patient’s life. Food and beverage consumption during the treatment may influence the measurements and the calculated fluid removal. In the present article the change observed in whole body and segmental (knee-to-knee, abdomen) BIS measur...
متن کاملTotal Body Water Changes Using Segmental Bioimpedance in Healthy Population with Similar Anthropometry
Electrical bioimpedance was measured in 7 body segments, and also with the standard right-side method, using 11 electrodes at 6 different frequencies in 8 healthy male subjects with similar anthropometry. Our objective was to determine the capability of segmental bioimpedance measurements to estimate small changes of water on each segment (TWsegi) and total body water (TBW) in comparison with t...
متن کاملInfluence of ambient temperature on whole body and segmental bioimpedance spectroscopy measurements
Bioimpedance spectroscopy (BIS) measurements are easy to implement and could be used for continuous monitoring. However, several factors (e.g. environment temperature) influence the measurements limiting the accuracy of the technology. Changes in skin temperature produced by changes in ambient temperature are related with changes in skin blood flow and skin impedance. It is assumed that skin im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 85 2 شماره
صفحات -
تاریخ انتشار 1998