Rapid assessment of in vivo cholinergic transmission by amperometric detection of changes in extracellular choline levels.

نویسندگان

  • Vinay Parikh
  • Francois Pomerleau
  • Peter Huettl
  • Greg A Gerhardt
  • Martin Sarter
  • John P Bruno
چکیده

Conventional microdialysis methods for measuring acetylcholine (ACh) efflux do not provide sufficient temporal resolution to relate cholinergic transmission to individual stimuli or behavioral responses, or sufficient spatial resolution to investigate heterogeneities in such regulation within a brain region. In an effort to overcome these constraints, we investigated a ceramic-based microelectrode array designed to measure amperometrically rapid changes in extracellular choline as a marker for cholinergic transmission in the frontoparietal cortex of anesthetized rats. These microelectrodes exhibited detection limits of 300 nm for choline and selectivity (> 100 : 1) of choline over interferents such as ascorbic acid. Intracortical pressure ejections of choline (20 mm, 66-400 nL) and ACh (10 and 100 mm, 200 nL) dose-dependently increased choline-related signals that were cleared to background levels within 10 s. ACh, but not choline-induced signals, were significantly attenuated by co-ejection of the acetylcholinesterase inhibitor neostigmine (Neo; 100 mm). Pressure ejections of drugs known to increase cortical ACh efflux, potassium (KCl; 70 mm, 66, 200 nL) and scopolamine (Scop; 10 mm, 200 nL), also markedly increased extracellular choline signals, which again were inhibited by Neo. Scop-induced choline signals were also found to be tetrodotoxin-sensitive. Collectively, these findings suggest that drug-induced increases in current measured with these microelectrode arrays reflect the oxidation of choline that is neuronally derived from the release and subsequent hydrolysis of ACh. Choline signals assessed using enzyme-selective microelectrode arrays may represent a rapid, sensitive and spatially discrete measure of cholinergic transmission.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Choline- and Acetylcholine-Sensitive Microelectrodes

The purpose of this chapter is to provide an overview of the use of enzyme-based microelectrodes and amperometric methods to detect and quantify extracellular levels of choline and acetylcholine (ACh). Our focus will be on the application and evolution of these biosensor techniques for use in vivo rather than the electrochemical principles underlying their development and operation. For the lat...

متن کامل

AMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE

The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...

متن کامل

Evaluation of Different Functionalized CNTs for Development of Choline Amperometric Biosensor

Choline oxidase (ChOx) was chosen as a model enzyme for evaluating the performance of CNTs’ functional groups for development of enzyme electrodes. CNTs were functionalized with carboxylic acid, amine or amide groups. Carboxylic acid, amine and amide functionalized CNTs were obtained by acid treatment, ethylenediamine or tetraethylenepentamine chemically modification and ammonia plasma treatmen...

متن کامل

Method of Production and Assessment of an Encapsulated Choline Chloride and Its Effects on Growth Performanc and Serum Lipid Indices in Broilers

Since, choline chloride caking causes serious operating difficulties and customer complaints, two experiments were conducted to optimize in vitro production of a novel encapsulated choline chloride (ECC) with minimum hygroscopic property and optimize delivery in gastrointestinal tract (GIT). The in vivo verification test of ECC was used to compare it with the commercial choline chloride (CC) in...

متن کامل

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European journal of neuroscience

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 2004