Study of PV-Trombe wall installed in a fenestrated room with heat storage
نویسندگان
چکیده
In this paper, a PV-Trombe wall (PV-TW) installed in a fenestrated room with heat storage is investigated to approach the practical application of PV-TW. Based on an updated mathematical model, theoretical simulation has been conducted for PV-TW in this case. Furthermore, field testing for this case has also been performed to validate the model, and then the simulated and experimental results are compared and found in considerably good agreement. The testing results show that a significant indoor temperature increase can be obtained in a fenestrated room with PV-TW and heat storage. Meanwhile, the experimental daily average electrical efficiency of this PVTW can reach 10.4%. 2006 Elsevier Ltd. All rights reserved.
منابع مشابه
Electrical and Thermal Characteristics of a Photovoltaic Solar Wall with Passive and Active Ventilation through a Room
Abstract—An experimental study was conducted for ascertaining electrical and thermal characteristics of a pair of photovoltaic (PV) modules integrated with solar wall of an outdoor room. A prefabricated outdoor room was setup for conducting outdoor experiments on a PV solar wall with passive and active ventilation through the outdoor room. The selective operating conditions for glass coated PV ...
متن کاملبهسازی حرارتی جدار ساختمانهای موجود در اقلیم سرد در ایران با بهرهگیری از ویژگیهای دیوار ترومب
This research is aimed to find an energy optimization method for existing buildings in cold climate regions of Iran. In the proposed system, a secondary skin is installed against the unglazed surfaces of the southern wall, creating a Trombe-wall. The sun-facing wall is then painted in black, and covered with a transparent material like clear glass, leaving a closed air gap between them. The res...
متن کاملSimultaneous estimation of heat fluxes applied to the wall of a channel with turbulent flow using inverse analysis
The main purpose of this study is to estimate the step heat fluxes applied to the wall of a two-dimensional symmetric channel with turbulent flow. For inverse analysis, conjugate gradient method with adjoint problem is used. In order to calculate the flow field, two equation model is used. In this study, adjoint problem is developed to conduct an inverse analysis of heat transfer in a channel...
متن کاملبررسی پارامتریک رفتار حرارتی استخر خورشیدی گرادیان نمک برای شرایط آب و هوایی شهر ارومیه
Solar pond technology is the easiest and the most economical system for converting and storing the solar heat energy. In this study, the effect of various parameters such as thickness of various layers, heat loss from the pond’s surface, the wall-shading effect and the pond size on the temperature of the storage zone were numerically investigated. The validity of the model is tested against exp...
متن کاملFree convection in a 3D chamber with local cooling and heating
This paper modeled heating air of a room through examining free convection in a 3D chamber. The chamber had cold and hot sources with Tc and Th temperatures, respectively. Its other walls were adiabatic. This study aimed at predicting effect of temperature difference, displacement of hot and cold sources and their aspect ratio on flow field, temperature and heat transfer rate. To conduct the st...
متن کامل