Standardization of ABO Antibody Titer Measurement at Laboratories in Korea

نویسندگان

  • Young Ae Lim
  • Seon Joo Kang
چکیده

BACKGROUND Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the methods and results of ABO Ab titers. METHODS The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recommended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). RESULTS Several interlaboratory variations were observed in the results, technical procedures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories (P=0.006) than the tube test. CONCLUSIONS Our study provides baseline data regarding the current status of ABO Ab titer measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used

BACKGROUND Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers. METHODS For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without di...

متن کامل

Impact of the baseline anti-A/B antibody titer on the clinical outcome in ABO-incompatible kidney transplantation.

BACKGROUND/AIMS We investigated the impact of the baseline anti-A/B antibody titer on the clinical outcome in ABO-incompatible kidney transplantation (IKT). METHODS We included 183 patients who had undergone KT (40 ABO IKT and 143 ABO-compatible KT). Eight patients with a baseline titer of ≥1:512 were assigned to the high-titer group and 32 patients with a baseline titer of ≤1:256 were assign...

متن کامل

Clinical study of the relationship between prenatal antibody titer and hemolytic disease of newborn

Hemolytic disease of newborn (HDN) is caused by the emergence of inappropriate antibodies against fetal blood antigens, which includes ABO and Rh blood group incompatibility. This study investigated the association between prenatal blood group antibody titer and HDN to provide a theoretic basis for clinical practice. ABO and Rh blood group of 7894 pregnant women and their husbands were screened...

متن کامل

Clinical analysis of single filtration plasmapheresis using continuous renal replacement therapy machines in kidney transplantation

BACKGROUND Plasmapheresis has become an essential element of kidney transplantation (KT). In the present study, we report clinical outcomes of filtration plasmapheresis using continuous renal replacement therapy machines with a single filter for the first time in Korea. METHODS We retrospectively analyzed six patients who underwent filtration plasmapheresis for KT in our center; plasmapheresi...

متن کامل

Effects of maternal serum IgG anti-A (B) and neonatal direct anti globulin red blood cell antibody expression on the occurrence and development of neonatal ABO haemolysis

Objectives: To explore the expression of maternal serum IgG anti-A (B) and neonatal direct anti globulin, free antibody and Red Blood Cell (RBC) antibody on the occurrence and development of ABO Haemolytic Disease of the New-born (ABO-HDN) and provide a valuable reference for the early diagnosis of the disease. Methods: we selected 546 cases of jaundice and hyperbilirubinemia neonates in our ho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2014