Comparison of central corneal thickness measured with anterior segment optical coherence tomography versus ultrasonic pachymetry.
نویسندگان
چکیده
PURPOSE To compare central corneal thickness measured with anterior segment optical coherence tomography (AS-OCT) and ultrasonic pachymetry (UP). METHOD A prospective, observational and cross-sectional study was performed. The central corneal thickness was measured in 112 eyes of 112 consecutive patients with AS-OCT and UP. All examinations were performed by the same examiner. The measurements obtained between the 2 instruments were compared to assess the level of agreement. RESULTS The average corneal thickness value obtained by AS-OCT was 531.47 ± 26.23 μm, while that measured by UP was 532.51 ± 26.04 μm. The intraclass correlation coefficient was 0.957 (P <.001). The Student's t-test did not show a statistically significant difference (1.04 ± 7.70 μm, P =.158). Finally, the Bland-Altman analysis showed a high level of agreement between 2 methods of measurement. CONCLUSIONS In the context of normal corneas, there was good agreement between the measurement of central corneal thickness with AS-OCT and UP, although there was a slight overestimation of the measurement using UP (1.04 μm).
منابع مشابه
Anterior Segment Time Domain Optical Coherence Tomography
To compare anterior segment parameters using quantitative imaging by anterior segment time domain optical coherence tomography (AS-OCT) and high frequency ultrasound biomicroscopy (HF-UBM). SETTING: Department of Ophthalmology at Bari University. METHODS: Seventy-two eyes of 72 subjects had anterior segment evaluation by AS-OCT (Stratus ver 6Zeiss) and HF-UBM (OTI-Scan HF35-50). Central corneal...
متن کاملComparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
BACKGROUND The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS Fifty...
متن کاملEvaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using Anterior Segment Optical Coherence Tomography.
BACKGROUND/AIMS To preliminarily evaluate the repeatability of central corneal thickness (CCT) measurements performed with Anterior Segment Optical Coherence Tomography (AS-OCT) on eye bank posterior corneal lenticules. METHODS Six donor lenticules were created with a 350 μm head microkeratome (Moria, Antony, France). All donor tissues were stored at 4°C in Eusol-C solution (Alchimia S.r.l, P...
متن کاملComparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology
PURPOSE The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. MATERIALS AND METHODS In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-...
متن کاملAnterior-segment optical coherence tomography investigation of corneal deturgescence and epithelial remodeling after DSAEK.
PURPOSE The aim of this study was to evaluate via Fourier-domain anterior-segment optical coherence tomography 3-dimensional corneal, epithelial, and graft thickness changes after Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS Sixteen eyes were investigated preoperatively and up to 6 months postoperatively for preoperative and postoperative central corneal thickness (C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 88 2 شماره
صفحات -
تاریخ انتشار 2013