Calibration method for multiangle lidar measurements.
نویسندگان
چکیده
A new method based on a two-angle approach is developed to determine the lidar solution constant from scanning elastic lidar data, hence providing a relative calibration for each lidar scan. Once the solution constant is determined, the vertical profiles of atmospheric extinction can be calculated. With this calibration method a minimization technique is used that replaces the linear regression used in a known two-angle approach that requires only local atmospheric homogeneity over a restricted altitude calibration range rather than overall horizontal homogeneity. Lidar signals from at least one pair of elevation angles are used, averaged in time when the system is operated in a permanent two-angle mode, or an arbitrary number of signal pairs is used, when a two-dimensional lidar scan is being processed. The method is tested extensively with synthetic data. The calibration method is a robust tool for determining the solution constant to the lidar equation and for obtaining vertical profiles of atmospheric extinction.
منابع مشابه
Multiangle lidar performance in the presence of horizontal inhomogeneities in atmospheric extinction and scattering.
The performance of single-ended multiangle lidar for measurements of atmospheric extinction andbackscattering is analyzed in the presence of shot noise. An algorithm for determining the transmission coefficient in the presence of horizontal inhomogeneities is described. The analysis indicates that real-time measurements of atmospheric properties with the multiangle lidar may be feasible even in...
متن کاملComparative Analysis of Two New Approaches for LiDAR System Calibration
LiDAR systems have been widely adopted for the acquisition of dense and accurate topographic data over extended areas. Although the utilization of this technology has increased in different applications, the development of standard methodologies for the calibration of LiDAR systems has not followed the same trend. Current in-flight calibration methods have the following drawbacks: (i) They are ...
متن کاملLiDAR-IMU Time Delay Calibration Based on Iterative Closest Point and Iterated Sigma Point Kalman Filter. Sensors 2017, 17, 539
The time delay calibration between Light Detection and Ranging (LiDAR) and Inertial Measurement Units (IMUs) is an essential prerequisite for its applications. However, the correspondences between LiDAR and IMU measurements are usually unknown, and thus cannot be computed directly for the time delay calibration. In order to solve the problem of LiDAR-IMU time delay calibration, this paper prese...
متن کاملRetrieval of aerosol backscatter and extinction from airborne coherent Doppler wind lidar measurements
A novel method for calibration and quantitative aerosol optical property retrieval from Doppler wind lidars (DWLs) is presented in this work. Due to the strong wavelength dependence of the atmospheric molecular backscatter and the low sensitivity of the coherent DWLs to spectrally broad signals, calibration methods for aerosol lidars cannot be applied to coherent DWLs usually operating at wavel...
متن کاملMultiangle observations of Arctic clouds from FIRE ACE: June 3, 1998, case study
In May and June 1998 the Airborne Multiangle Imaging Spectroradiometer (AirMISR) participated in the FIRE Arctic Cloud Experiment (ACE). AirMISR is an airborne instrument for obtaining multiangle imagery similar to that of the satellite-borne MISR instrument. This paper presents a detailed analysis of the data collected on June 3, 1998. In particular, AirMISR radiance measurements are compared ...
متن کاملذخیره در منابع من