3D treatment planning and intensity-modulated radiation therapy.

نویسنده

  • J A Purdy
چکیده

Three-dimensional (3D) image-based treatment planning and new delivery technologies have spurred the implementation of external beam radiation therapy techniques, in which the high-dose region is conformed much more closely to the target volume than previously possible, thus reducing the volume of normal tissues receiving a high dose. This form of external beam irradiation is referred to as 3D conformal radiation therapy (3DCRT). 3DCRT is not just an add-on to the current radiation oncology process; it represents a radical change in practice, particularly for the radiation oncologist. Defining target volumes and organs at risk in 3D by drawing contours on CT images on a slice-by-slice basis, as opposed to drawing beam portals on a simulator radiograph, can be challenging, because radiation oncologists are generally not well trained in cross-sectional imaging. Currently, the 3DCRT approach will increase the time and effort required by physicians inexperienced with 3D treatment planning. Intensity-modulated radiation therapy (IMRT) is a more advanced form of 3DCRT, but there is considerable developmental work remaining. The instrumentation and methods used for IMRT quality assurance procedures and testing are not well established. Computer optimization cost functions are too simplistic, and thus time-consuming. Subjective plan evaluation by the radiation oncologist is still the norm. In addition, many fundamental questions regarding IMRT remain unanswered. For example, the radiobiophysical consequences of altered time-dose-fraction are unknown. Also, the fact that there is much greater dose heterogeneity for both the target and normal critical structures with IMRT compared to traditional irradiation techniques challenges current radiation oncology planning principles. However, this new process of planning and treatment delivery shows significant potential for improving the therapeutic ratio. In addition, while inefficient today, these systems, when fully developed, will improve the efficiency with which external beam radiation therapy can be planned and delivered, thus lowering costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer

Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...

متن کامل

Out-of-field photon dosimetry study between 3-D conformal and intensity modulated radiation therapy in the management of prostate cancer

Background: The present work aims to study the out-of-field photon calculation accuracy of a commercial treatment planning system (TPS), Oncentra, for three-dimensional conformal radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) treatment techniques from Elekta Synergy medical linear accelerator. Materials and Methods: Accuracy of individual out-of-field dose components was...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oncology

دوره 13 10 Suppl 5  شماره 

صفحات  -

تاریخ انتشار 1999