Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
نویسندگان
چکیده
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research.
منابع مشابه
Reliability of concentric and eccentric strength of hip abductor and adductor muscles in young soccer players
The concentric and eccentric strength profile and muscular balance of the hip joint are important parameters for success in soccer. This study evaluated the reliability for the assessment of hip abduction and adduction isokinetic strength over a range of angular velocities (30 and 90°/s) and types of muscular actions (concentric and eccentric) in young soccer players. The reliability for the as...
متن کاملTest-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke.
OBJECTIVE To i the test-retest reliability of isokinetic strength measurements of 3 muscle groups of the lower extremities in stroke patients. DESIGN Isokineth tests of bilateral hip flexors, knee extensors, and ankle plantarflexors at 2 angular velocities, performed during 2 sessions scheduled 1 week apart for each subject. SETTING Outpatilitation clinic of a local hospital in Taiwan. PA...
متن کاملRetest reliability of measuring hip extensor muscle strength in different testing positions in young people with cerebral palsy
BACKGROUND In young people with spastic diplegic cerebral palsy weakness of the hip extensor muscles are associated with limitations in activity. It is important that clinicians can reliably measure hip extensor muscle strength to monitor changes over time and the effects of any interventions. Previous research has demonstrated high reliability for measuring strength of all muscles of the lower...
متن کاملThe strength of hip abductor and external rotator muscles and ACL rupture in male soccer players
The purpose of this study was to compare of hip abductor and external rotator muscles strength between male soccer players with ACl rupture and healthy male soccer players. 30 male participants (15 soccer players with ACL rupture as sample group and 15 healthy soccer players as control group) participated in this study. Hip abductor and external rotator muscles strength tests including nor...
متن کاملIntra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis.
OBJECTIVE To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN Intra-rater test-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS Patients with hi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013