In Vivo Measurement of Hypoxia in Brain Tumors by qBOLD MRI Methods

نویسندگان

  • J. R. Garbow
  • S. C. Jost
  • X. He
  • D. A. Yablonskiy
چکیده

Introduction: Tumor hypoxia and its downstream effects are of considerable interest in both basic and clinical oncology research due to their negative impact on response to various cancer therapies and promotion of metastasis. Diagnosing tumor hypoxia non-invasively could provide a significant advancement in cancer treatment and will be key to implementing emerging targeted therapies that will treat cancer while minimizing the negative impacts of this hypoxia [1,2]. While a variety of techniques have been proposed to measure hypoxia non-invasively, none have been established clinically. Our approach to quantifying tumor hypoxia is based on a recently proposed Quantitative Blood Oxygenation Level Dependent (qBOLD) model of BOLD contrast in MRI [3]. Here we report the results of an initial study of tumor hypoxia in a mouse model of high-grade glioma. Methods: All experiments were performed on a dedicated 4.7 T Varian small-animal MRI scanner using a 2.5 cm ID quadrature birdcage RF coil. All surgical procedures were conducted under the guidelines of the Washington University Institutional Animal Care and Use Committee. Mouse DBT glioblastoma cells were implanted into the brains of female Balb/c mice as previously described [4]. Briefly, cells were plated in T-75 culture flasks for incubation in a 5% CO2 humidified atmosphere at 37 °C and used at low passages. Mice were anesthetized with intraperitoneal 25 mg/kg ketamine, 5 mg/kg xylazine, and 2.5 mg/kg acepromazine prior to intracranial DBT cell implantation. After a midline scalp incision, a 1-mm cutting burr was used to make a craniostomy over the cortex. Mice were secured in a stereotactic frame and 5 μl of DBT tumor cell suspension (5 × 10**4 cells) were aspirated into a Hamilton syringe attached to the frame. The syringe was inserted into the brain and the tumor cells were injected over three minutes. The craniostomy hole was secured with bone wax and the incision was closed with a dermal adhesive. Prior to each imaging experiment, mice were anesthetized with isoflurane/O2 [3% (v/v)], and maintained on isoflurane [1.5% (v/v)] in a gas mixture of 20%O2 /80% N2 throughout the experiment. A 3D version of gradient echo sampling of spin echo sequence (GESSE) [3] was employed. Data acquisition was performed using the following acquisition parameters: FOV 18x18x18 mm, sampling matrix of 64x64x32, TR of 200 msec, NEX of 8. The spin echo occurs at the 11 of 31 echoes (56 msec after excitation). All 3D MR data were filtered by a Hanning filter to improve SNR and to reduce the Fourier leakage. The MR signal was analyzed using a qBOLD model [3] that includes signals from tissue, deoxygenated blood, and CSF. In particular, the free induction decay of MR signal from the brain tissue was described in terms of the BOLD model [5] and the signal from the deoxygenated blood was modeled as originating from a network of randomly oriented cylindrical blood vessels [6]. Results and Discussion: Mice were imaged using the GESSE sequence at days 4, 11, 14, and 17 following injection of the DBT cells. The figure below shows a representative single slice from a contrast-enhanced T1-weighted image (left) and map of the estimated oxygen extraction fraction (OEF) of a mouse on day 14 following injection of DBT cells. The color bar on the right shows OEF in %. Tumor is clearly visible in the upper right portion of the brain; while a clear elevation in OEF is seen in the tumor area, corresponding to tumor hypoxia. Similar results were obtained for all other mice imaged in this study, with regions of hypoxia correlating closely in both size and location with observed tumors. These results serve to establish the feasibility and importance of qBOLD-based methods for quantitatively measuring hypoxia in developing tumors in mouse models of brain tumors. We anticipate that these methods can be readily translated to clinical studies of patients with high-grade brain tumors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of oxygen extraction fraction measurement by qBOLD technique.

Measurement of brain tissue oxygen extraction fraction (OEF) in both baseline and functionally activated states can provide important information on brain functioning in health and disease. The recently proposed quantitative BOLD (qBOLD) technique is MRI-based and provides a regional in vivo OEF measurement (He and Yablonskiy, MRM 2007, 57:115-126). It is based on a previously developed analyti...

متن کامل

Evaluation of Diagnostic Value of CT Scan and MRI in Brain Tumors and Comparison with Biopsy

Abstract Background Cerebral neoplasm arises from brain, spinal cord and meningeal cells. Not only malignant cerebral neoplasm also benign tumor could lead to death due to mass effect on vital structures. Access to these tumors is difficult, and MRI and CT scan could be helpful in determining anatomical location of tumors and distinction of malignant from benign. Objective For better and ea...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Verification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors

Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong  relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In  many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general,  the uncertainty in the dose delivered should fall within  ± 5% of the...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007