Evaluation of left ventricular diastolic function with a dedicated cadmium-zinc-telluride cardiac camera: comparison with Doppler echocardiography.

نویسندگان

  • Alessia Gimelli
  • Riccardo Liga
  • Emilio Maria Pasanisi
  • Assuero Giorgetti
  • Gavino Marras
  • Brunella Favilli
  • Paolo Marzullo
چکیده

AIMS To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND RESULTS Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardiography study. All patients were submitted to invasive or computed coronary angiography. The peak filling rate (PFR) and the time to PFR (TPFR) were derived from gated CZT images as measures of LV filling dynamics. LV diastolic function was also evaluated at echocardiography and the presence of significantly increased LV filling pressures determined. Increased LV filling pressures at transthoracic echocardiography were evident in 103 (42%) patients. Interestingly, independently from the presence of coronary artery disease, there was a strict correlation between the presence and severity of LV diastolic dysfunction at echocardiography and CZT-derived measures of filling dynamics, i.e., PFR (P = 0.001) and TPFR (P = 0.001). At receiving operating characteristic analysis, a composite index of reduced PFR (≤2.11 end-diastolic volume s(-1)) and increased TPFR (>234 ms) showed a sensitivity of 84% and a specificity of 67% in unmasking the presence of elevated LV filling pressures at echocardiography. CONCLUSIONS CZT-derived measures of LV filling dynamics correlate with echocardiographic parameters of diastolic function and may identify the presence of increased LV filling pressures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method

Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...

متن کامل

LEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION

In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...

متن کامل

بررسی عوارض قلبی در بیماران مبتلا به تالاسمی ماژور در کاشان در سالهای 1378 لغایت 1379

ABSTRACT Due to the frequency of major thalassemia in our country and cardiac complications secondry to iron overload as one of the most important causes of death in these patients and the absence of any similar study in this region (Kashan city), we studied the cardiac complications in patients with major thalassemia in Kashan in 1999 and 2000. A prospective descriptive study was perf...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 15 9  شماره 

صفحات  -

تاریخ انتشار 2014