Multivariate Analysis of the Ocular Response Analyzer's Corneal Deformation Response Curve for Early Keratoconus Detection
نویسندگان
چکیده
Purpose. To thoroughly analyze corneal deformation responses curves obtained by Ocular Response Analyzer (ORA) testing in order to improve subclinical keratoconus detection. Methods. Observational case series of 87 control and 73 subclinical keratoconus eyes. Examination included corneal topography, tomography, and biomechanical testing with ORA. Factor analysis, logistic regression, and receiver operating characteristic curves were used to extract combinations of 45 corneal waveform descriptors. Main outcome measures were corneal-thickness-corrected corneal resistance factor (ccCRF), combinations of corneal descriptors, and their diagnostic performance. Results. Thirty-seven descriptors differed significantly in means between groups, and among them ccCRF afforded the highest individual diagnostic performance. Factor analysis identified first- and second-peak related descriptors as the most variable one. However, conventional biomechanical descriptors corneal resistance factor and hysteresis differed the most between control and keratoconic eyes. A combination of three factors including several corneal descriptors did not show better diagnostic performance than a combination of conventional indices. Conclusion. Multivariate analysis of ORA signals did not surpass simpler models in subclinical keratoconus detection, and there is considerable overlap between normal and ectatic eyes irrespective of the analysis model. Conventional biomechanical indices seem to already provide the best performance when appropriately considered.
منابع مشابه
ویژگیهای بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری
Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...
متن کاملEvaluation of Ocular Biomechanical Indices to Distinguish Normal from Keratoconus Eyes
Purpose: To compare and assess the ability of pressure-derived parameters and corneal deformation waveform signal-derived parameters of the ocular response analyzer (ORA) measurement to distinguish between keratoconus and normal eyes, and to develop a combined parameter to optimize the diagnosis of keratoconus. Materials and methods: One hundred and seventy-seven eyes (177 patients) with kerato...
متن کاملRisk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty
Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...
متن کاملCorneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature
The Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Buffalo, NY) allows direct measurement of corneal biomechanical properties. Since its introduction, many studies have sought to elucidate the clinical applications of corneal hysteresis (CH) and corneal resistance factor (CRF). More recently, detailed corneal deformation signal waveform analysis (WA) has potentially expanded t...
متن کاملEvaluation of total and corneal wavefront high order aberrations for the detection of forme fruste keratoconus.
PURPOSE To investigate the application of anterior corneal and ocular aberrations in detecting mildly ectatic corneas. METHODS This study retrospectively reviewed the data of 220 eyes separated into three groups by the NIDEK Corneal Navigator System automated corneal classification software: normal (N) (n = 123); forme fruste keratoconus (N topography with contralateral KC) (n = 34); and KC (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015