A comparison of manual and automated methods of measuring airway resistance and thoracic gas volume.

نویسندگان

  • P W Lord
  • A G Brooks
چکیده

An automated method of measuring airways resistance (Raw) and thoracic gas volume (Vtg) by whole body plethysmography using a digital computer is described. The results obtained by this method are compared with those obtained by an experienced observer and the results of consistency tests on the two methods are given. There was wide variability in the values of Raw obtained using each method, and no significant differences were found between the two methods. The values of Vtg obtained by them were highly correlated, but the results obtained manually were higher than those obtained automatically by an amount proportional to the volume. The consistency of the computer measurements was shown to be greater than that of the manual method. A significant decrease between successive measurements of Raw in some subjects was noted in the manual observations but not in those derived from the automated method. The new method is suitable for the rapid determination of Raw and Vtg.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variation between observers in the estimation of airway resistance and thoracic gas volume.

Variations in the estimation of airway resistance (Raw) and thoracic gas volume (Vtg) made by different observers using body plethysmography have been investigated. Five observers determined Raw and Vtg in normal subjects using prerecorded signals so that intrasubject variations were eliminated. The slopes of the oscillography tracings required to make the determinations were assessed using a c...

متن کامل

Fragmentation measurement using image processing

In this research, first of all, the existing problems in fragmentation measurement are reviewed for the sake of its fast and reliable evaluation. Then, the available methods used for evaluation of blast results are mentioned. The produced errors especially in recognizing the rock fragments in computer-aided methods, and also, the importance of determination of their sizes in the image analysis ...

متن کامل

Effect of Bone Borne Expansion and Tooth Borne Palatal Expansion on Airway Volume: A Review Article

Background and purpose: Transverse problems in the maxilla (high arched- narrow hard plates) can cause respiratory disorders. Palatal expansion can be helpful in this way. The present study aimed at evaluating the effect of bone borne expansion and tooth borne palatal expansion on airway volume. Materials and methods: A review study was performed by search in Google Scholar, Scopus, PubMed, Em...

متن کامل

Pharyngeal Airway: An Analysis Using 2D vs. 3D Images in Different Malocclusions

Introdouction: The aim of this study was to compare information regarding pharyngeal airway sizes in adolescent subjects with different malocclusion classes obtained from lateral cephalograms and 3–dimensional (3D) cone-beam computed tomography (CBCT) scans. Materials and methods: In this prospective cross-sectional study, CBCT scans and lateral cephalograms of 35 subjects, taken with...

متن کامل

Airway responsiveness following wheezy bronchitis in infants.

The study was undertaken to assess the airway function and its response to carbachol and salbutamol in infants recovering from wheezy bronchitis. In 82 children aged 3-33 mths, free from wheeze at the time of testing, and in 14 healthy infants, airway resistance (Raw) and thoracic gas volume (TGV) were measured using a body plethysmograph. Specific airway resistance (sRaw = Raw x TGV) was calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 1977