CoaguChek point-of-care testing prothrombin time monitors.

نویسنده

  • Sigmund Lorenz Braun
چکیده

A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by experienced staff at 9 Netherlands Thrombosis Centers and results compared with certified INR. A 15% or more deviation has been classified as significant deviation. Overall mean and certified INR values were similar, but 20.3% of participants showed a 15% or more deviation from the certified INR on at least 1 of the 5 QA plasma samples. Statistically significant differences in results with different lots of CoaguChek test strips were found. There is need for large scale QA of CoaguChek monitors. The importance of the 5 CoaguChek certified INR QA plasma samples being tested on a single occasion is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assessment of CoaguChek point-of-care prothrombin time monitors: comparison of the European community-approved procedure and conventional external quality assessment.

BACKGROUND There is a need for dependable quality assessment (QA) of the widely used CoaguChek point-of-care testing prothrombin time monitor. By use of the prescribed set of 5 CoaguChek certified international normalized ratio (INR) QA plasmas, we compared the reliability of the immediate QA of individual monitors described in the European Community-recommended Technology Implementation Plan w...

متن کامل

A National Field Study of Quality Assessment of CoaguChek Point-of-Care Testing Prothrombin Time Monitors

A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...

متن کامل

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma...

متن کامل

Evaluation of a Method for International Sensitivity ndex Calibration of Two Point-of-Care Prothrombin Time (PT) Monitoring Systems (CoaguChek Mini and TAS PT-NC) with Fresh Plasmas Based on Whole-Blood Equivalent PT

Background: The International Sensitivity Index (ISI) calibration of whole-blood prothrombin time (PT) monitors for point-of-care testing (POCT) described by Tripodi et al. (Thromb Haemost 1993;70:921–4) has been shown to be dependable but is too complex and demanding. The use of plasma would simplify calibration of whole-blood POCT PT monitors, but important differences may exist between the I...

متن کامل

European concerted action on anticoagulation. Quality assessment of the CoaguChek Mini and TAS PT-NC point-of-care whole-blood prothrombin time monitors.

BACKGROUND International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the "true" INR. There is therefore a need for local quality assessment (QA) of the two systems. METHODS A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 cent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 126 5  شماره 

صفحات  -

تاریخ انتشار 2006