Gas chromatographic determination of Ostwald solubility coefficients for cyclopropane, halothane and trichloroethene (trichloroethylene).
نویسندگان
چکیده
Gas chromatographic methods using solvent extraction for the analysis of cyclopropane and and trichloroethene (trichloroethylene) are described and evaluated; cyclopropane was extracted into carbon tetrachloride and trichloroethene into carbon disulphide, using chloroform and toluene respectively as the internal standards. Ostwald solubility coefficients were measured for cyclopropane, halothane and trichloroethene in Krebs solution: at 310 K the respective values +/- SEM of the Ostwald coefficients are 0.181 +/- 0.009, 0.78 +/- 0.02 and 1.54 +/- 0.02; over the temperature range 295-310 K the respective temperature coefficients of solubility are -2.27, -4.18 and -3.81 in units of per cent/K at 310 K.
منابع مشابه
The Sensitivity of the Respiratory Tract during Anaesthesia in the Cat.
In cats the sensitivity of the respiratory tract to stimulation with diethyl ether was studied during nitrous oxide, cyclopropane, halothane and trichloroethylene anaesthesia. Nitrous oxide caused little change in sensitivity; halothane and trichloroethylene caused a gradually decreasing sensitivity; and cyclopropane depressed the response only in deep anaesthesia. In addition, following stimul...
متن کاملA method for the gas chromatographic analysis of inhalation anaesthetics in whole blood by direct injection into a simple precolumn device.
A simple heated precolumn device constructed from standard gas chromatographic components is described and evaluated. The device permits the analysis of concentrations of anaesthetic agents by direct injection of whole blood containing a suitable internal standard. A method is described for the analysis of halothane, chloroform, trichloroethylene, and methoxyflurane. The procedure is rapid and ...
متن کاملBr.J. Anaesth. (1975), 47, 1043 A METHOD FOR THE GAS CHROMATOGRAPHIC ANALYSIS OF INHALATION ANAESTHETICS IN WHOLE BLOOD BY DIRECT INJECTION INTO A SIMPLE PRECOLUMN DEVICE
A simple heated precolumn device constructed from standard gas chromatographic components is described and evaluated. The device permits the analysis of concentrations of anaesthetic agents by direct injection of whole blood containing a suitable internal standard. A method is described for the analysis of halothane, chloroform, trichloroethylene, and methoxyflurane. The procedure is rapid and ...
متن کاملOstwald solubility coefficients of some industrially important substances.
Solubility coefficients in blood for benzene, toluene, and xylene were determined as 6.5, 16, and 42 respectively. In lard and olive oil, which were taken to represent human fat, corresponding values were about 450, 1300, and 3900. The coefficient for vinyl chloride in lard and olive oil was 20; the value in blood was too low to be determined by the technique used. Trichloroethylene, used as a ...
متن کاملThe uptake and elimination of halothane in dogs: a two- or multicompartment system? I: Gas chromatographic determination of halothane in blood and in inspired and end-tidal gases.
The gas chromatographic determination of volatile organic anaesthetic agents in blood and in respiratory gases is described. The analysis in blood is based on a head space technique. Sampling of inspired and end-tidal gases is carried out by means of a system including a gas sampling valve.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 49 5 شماره
صفحات -
تاریخ انتشار 1977