Study of the adjustment of the Ambu laryngeal mask under magnetic resonance imaging.
نویسندگان
چکیده
BACKGROUND Our aim in this study was to analyze the adjustment of the laryngeal mask, Ambu AuraOnce, in pediatric patients during magnetic resonance imaging (MRI) and to look for a correlation between clinical parameters such as the sealing pressure and the ease of introduction with radiological parameters. METHODS One-hundred and twenty-one pediatric patients from 4 months to 17 years who required a cranial MRI for other reasons were enrolled in the study. General anesthesia was induced with sevofluorane and no relaxant was used. Insertion attempts, sealing pressure, desaturation episodes and maintenance of anesthesia were recorded. Spontaneous ventilation was maintained throughout all procedures and no episodes of desaturation below 95% were seen. Patients without cough or pharyngeal pain were discharged after 1 h. Data were classified into three groups according to the size of the used laryngeal mask (group 1 for laryngeal mask number 1(1/2); group 2 for laryngeal mask number 2, and group 3 for laryngeal mask number 2(1/2)). Sagittal MRI cuts were reviewed to calculate neck flexion, laryngeal mask position and its relationship with the trachea. RESULTS First-attempt introduction rate of the laryngeal mask was 96%, and it was 100% after a second attempt. Sealing pressure was 22.1+/-4.15 mmHg for group 1, 22.23+/-3.94 for group 2, and 23.83+/-3.28 for group 3. The angles between the laryngeal mask and the four first cervical vertebrae were calculated (group 1, 33.65+/-8.05; group 2, 28.09+/-6.65; group 3, 25.79+/-4.26). Distances between trachea and proximal and distal cuffs were measured to evaluate proper fitting of the laryngeal mask. Anomalous placement seen on MRI, using distances from proximal and distal cuff to trachea, occurred in 23.5% in group 1, 10.9% in group 2, and 13.8% in group 3. We found no correlation between this anomalous position of the laryngeal mask and sealing pressure or ease of introduction. CONCLUSIONS The Ambu AuraOnce can be regarded as a safe product for airway maintenance in pediatric patients. No relationship was found between radiological measurements and sealing pressures.
منابع مشابه
Comparison between LMA-Classic and AMBU AuraOnce laryngeal mask airway in patients undergoing elective general anaesthesia with positive pressure ventilation.
BACKGROUND The LMA-Classic laryngeal mask airway (Classic LMA) is an autoclavable and reusable laryngeal mask airway with strong evidence supporting its efficacy and safety. Due to the concern of infection risk particularly of prion disease, various single-use laryngeal mask devices were developed. The Ambu AuraOnce LMA (Ambu LMA) is a single use disposable laryngeal mask airway with special de...
متن کاملRandomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I-IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic an...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملIron-gold (Fe2O3@Au) core-shell nano-theranostic for magnetically targeted photothermal therapy under magnetic resonance imaging guidance
Introduction: Photothermal therapy (PTT) is a nanotechnology-assisted cancer hyperthermia approach in which the interaction between laser light and plasmonic nanoparticles generates a localized heating for thermoablation of the tumor. Recent efforts in the area of PTT follow two important aims: (i) exploitation of targeting strategies for preferential accumulation of plasmonic ...
متن کاملComparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures.
BACKGROUND AND OBJECTIVE This study was performed to compare three disposable airway devices, the LMA Unique (LMA-U), the Ambu laryngeal mask (Ambu LM) and the Soft Seal laryngeal mask (Soft Seal LM) for elective general anaesthesia during controlled ventilation in non-paralysed patients. METHODS One hundred and twenty ASA I-III patients scheduled for routine minor obstetric surgery were rand...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Paediatric anaesthesia
دوره 17 12 شماره
صفحات -
تاریخ انتشار 2007