Enhancement Effect of a Variable Topology of a Membrane-Tethered Anti-Poly(ethylene glycol) Antibody on the Sensitivity for Quantifying PEG and PEGylated Molecules.

نویسندگان

  • Wen-Wei Lin
  • Yi-An Cheng
  • Chien-Han Kao
  • Steve R Roffler
  • Yu-Chi Lee
  • Bing-Mae Chen
  • Yuan-Chin Hsieh
  • I-Ju Chen
  • Bo-Cheng Huang
  • Yeng-Tseng Wang
  • Yi-Ching Tung
  • Ming-Yii Huang
  • Fang-Ming Chen
  • Tian-Lu Cheng
چکیده

Sensitive quantification of the pharmacokinetics of poly(ethylene glycol) (PEG) and PEGylated molecules is critical for PEGylated drug development. Here, we developed a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) for PEG by tethering an anti-PEG antibody (AGP3) via tethers with different dimensions on the surface of 293T cells (293T/S-αPEG, short-type cells; 293T/L-αPEG, long-type cells; 293T/SL-αPEG, hybrid-type cells) to improve the binding capacity and detection limit for free PEG and PEGylated molecules. The binding capacity of hybrid-type cells for PEG-like molecules (CH3-PEG5K-FITC (FITC = fluorescein isothiocyanate) and eight-arm PEG20K-FITC) was at least 10-80-fold greater than that of 293T cells expressing anti-PEG antibodies with uniform tether lengths. The detection limit of free PEG (OH-PEG3K-NH2 and CH3-PEG5K-NH2) and PEG-like molecule (CH3-PEG5K-FITC, CH3-PEG5K-SHPP, and CH3-PEG5K-NIR797) was14-137 ng mL-1 in the hybrid-type cell-based sandwich ELISA. 293T/SL-αPEG cells also had significantly higher sensitivity for quantification of a PEGylated protein (PegIntron) and multiarm PEG macromolecules (eight-arm PEG20K-NH2 and eight-arm PEG40K-NH2) at 3.2, 16, and 16 ng mL-1, respectively. Additionally, the overall binding capacity of 293T/SL-αPEG cells for PEGylated macromolecules was higher than that of 293T/S-αPEG or 293T/L-αPEG cells. Anchoring anti-PEG antibodies on cells via variable-length tethers for cell-based sandwich ELISA, therefore, provides a sensitive, high-capacity method for quantifying free PEG and PEGylated molecules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of poly(ethylene glycol) by cell-based anti-poly(ethylene glycol) ELISA.

Poly(ethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/alphaPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification...

متن کامل

Effect of Ethylene Oxide Functional Groups in PEBA-CNT Membranes on CO2/CH4 Mixed Gas Separation

Poly (ether-block-amide) /poly (ethylene glycol)/ carbon nanotubes mixed matrix membranes have been successfully fabricated using solvent evaporation method to determine the effect of ethylene oxide groups on the performance of produced membranes. The effects of CNTs (2-8 wt%) and PEG (up to 50 wt%)were investigated in both single and mixed gas test setup in different temperature and pressure. ...

متن کامل

Fabrication of (Acrylonitrile Butadiene Styrene/Poly Ethylene Glycol) Nanofiltration Membrane: the Effect of PEG Concentration and Operating Conditions on Membrane Performance

In the current research, ABS-co-PEG nanofiltration membrane was prepared by solution casting technique using N, N dimethyl acetamide as solvent. The effect of PEG concentration as additive in the casting solution on membrane flux, salt rejection, phase inversion time, water content, membrane porosity, membrane tensile strength and fouling was studied. Also the eff...

متن کامل

Co-immobilized poly(ethylene glycol)-block-polyamines promote sensitivity and restrict biofouling on gold sensor surface for detecting factor IX in human plasma.

In order to detect an extremely low amount of human coagulation factor IX (FIX), poly(ethylene glycol) (PEG)/aptamer co-immobilized surface was constructed using original PEG-polyamine surface modification agents on surface plasmon resonance (SPR) sensor chip. Initially, a gold (Au) sensor chip of SPR was modified using poly(ethylene glycol)-b-poly[2-(N,N-dimethylamino)ethyl methacrylate] (PEG-...

متن کامل

Sensitivity of PEGylated interferon detection by anti-polyethylene glycol (PEG) antibodies depends on PEG length.

Attachment of poly(ethylene glycol) to proteins can mask immune epitopes to increase serum half-life, reduce immunogenicity, and enhance in vivo biological efficacy. However, PEGylation mediated epitope-masking may also limit sensitivity and accuracy of traditional ELISA. We previously described an anti-PEG-based sandwich ELISA for universal assay of PEGylated molecules. Here, we compared the q...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 89 11  شماره 

صفحات  -

تاریخ انتشار 2017