A new method for attenuation coefficient measurement in the liver: comparison with the spectral shift central frequency method.

نویسندگان

  • Yasutomo Fujii
  • Nobuyuki Taniguchi
  • Kouichi Itoh
  • Kouichiro Shigeta
  • Yi Wang
  • Jing-Wen Tsao
  • Kenji Kumasaki
  • Takashi Itoh
چکیده

OBJECTIVE To assess the feasibility of a new method of measuring the attenuation coefficient in the liver, which offers less variability of results than the conventional method. METHODS The attenuation coefficient was evaluated on the basis of the following equation with sound field correction: [log(M0 (z)) - tau(z)]. In our system, the attenuation coefficient was also evaluated by the spectral shift central frequency method at the same time. We used 44 cases of normal liver, 40 cases of fatty liver, and 20 cases of cirrhotic liver in the system. RESULTS With this new method, attenuation coefficient values were 0.59+/-0.10 dB x cm(-1) x MHz(-1) in normal livers, 0.80+/-0.12 dB x cm(-1) x MHz(-1) in fatty livers, and 0.62+/-0.09 dB x cm(-1) x MHz(-1) in cirrhotic livers. In both methods we recorded a statistically significant difference between normal and fatty livers and between fatty and cirrhotic livers (P < .0001). Only in the fatty liver was any significant difference (P < .0001) found between attenuation coefficients in the new method and those in the spectral shift central frequency method (0.70+/-0.05 dB x cm(-1) x MHz(-1)). CONCLUSIONS This new method, which was more sensitive in detecting fatty infiltration than the spectral shift central frequency method, was considered usable for evaluating the attenuation coefficient of the liver in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DETERMINATION OF ATTENUATION RELATIONSHIPS USING AN OPTIMIZATION PROBLEM

The main objective of this study is to present new method on the basis of genetic algorithms for attenuation relationship determination of horizontal peak ground acceleration and spectral acceleration. The proposed method employs the optimization capabilities of genetic algorithm to determine the coefficients of attenuation relationships of peak ground and spectral accelerations. This method ha...

متن کامل

Large Amplitude Vibration Analysis of Graphene Sheets as Resonant Mass Sensors Using Mixed Pseudo-Spectral and Integral Quadrature Methods

The present paper investigates the potential application of graphene sheets with attached nanoparticles as resonant sensors by introducing a nonlocal shear deformation plate model. To take into account an elastic connection between the nanoplate and the attached nanoparticle, the nanoparticle is considered as a mass-spring system. Then, a combination of pseudo-spectral and integral quadrature m...

متن کامل

An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...

متن کامل

Hybrid spectral domain method for attenuation slope estimation.

Attenuation estimation methods for medical ultrasound are important because attenuation properties of soft tissue can be used to distinguish between benign and malignant tumors and to detect diffuse disease. The classical spectral shift method and the spectral difference method are the most commonly used methods for the estimation of the attenuation; however, they both have specific limitations...

متن کامل

Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation.

PURPOSE Quantitative ultrasound based approaches such as attenuation slope estimation can be used to determine underlying tissue properties and eventually used as a supplemental diagnostic technique to B-mode imaging. The authors investigate the impact of backscatter intensity and frequency dependence variations on the attenuation slope estimation accuracy. METHODS The authors compare three f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2002