Drill and Jig Design to Improve Cement Fixation of the Acetabular Cup During Total Hip Replacement

نویسندگان

  • R. Mootanah
  • E. Allen
  • P. Ingle
  • K. Cheah
  • J. Dowell
  • J. C. Shelton
چکیده

Successful replacement of hips is the only solution for severe degenerative diseases such as osteoarthritis (Bird, 1995). During cemented fixation of the acetabular cup, anchorage holes are drilled in the acetabulum, then cement is introduced and pressurised to create cement pegs within the anchorage holes. During physiological activities, the bone cement interface of the acetabulum experiences high compressive and shear stresses (Harkess, 1998) and therefore the anchorage holes have a major contribution in improving the stability and the torsional strength of the cemented acetabular component. The efficiency of these holes depends upon the stress distribution around the neck of the cement peg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Migration of a Broken Drill Bit After Acetabular Fracture Fixation.A Case report

Breakage of the drill bit is common in orthopaedic procedures, but migration of the broken drill bit is rarely reported. We report a case of migration of a broken drill bit five years after acetabular fracture fixation. The drill bit migrated to the subcutaneous layer of the anterior aspect of the right hip following total hip replacement. We highlight this case as it could be encountered in an...

متن کامل

The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests

BACKGROUND Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups. METHODS Acetabular cups with different geometries (Link: IP and Lubinus eccentric) were tested cy...

متن کامل

Influence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.

Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...

متن کامل

Femoral and obturator nerves palsy caused by pelvic cement extrusion after hip arthroplasty

Cement extrusion into the pelvis with subsequent palsy of the obturator and femoral nerves is a rare entity after hip replacement surgery. Cemented fixation of the acetabular cup has been considered as a safe and reliable standard procedure with very good long term results. We present a case of fifty year old female patient after hip arthroplasty procedure which suffered an obturator and femora...

متن کامل

The Stability of Acetabular Cup under Screw Fixation

INTRODUCTION The total hip replacement is a common surgical procedure in orthopaedics. However, the acetabular cup loosening is one of the major failure modes of cementless acetabular cup. Many researches point out that an unstable cup would induce a large micromotion under dynamic loading. This large micromotion would reduce the bone ongrowth on the cementless cup surface and prohibit the osse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001