Influence of lubricant on screw preload and stresses in a finite element model for a dental implant.
نویسندگان
چکیده
STATEMENT OF PROBLEM Loosening or fracture of the abutment screw are frequent complications in implant dentistry and are detrimental to the long-term success of the restorations. However, little is known about the factors influencing the stability of the screw-abutment complex. PURPOSE The purpose of this study was to investigate the influence of lubricant action during implant assembly on screw preload and stresses in a dental implant-abutment complex. MATERIAL AND METHODS A dental implant was modeled for finite element stress analysis. Different friction coefficients (μ=0.2 to 0.5) were chosen for the interfaces between implant components to simulate lubricant action or dry conditions. The stress analyses were each divided into 2 load steps. First, the abutment screw was virtually tightened with a torque of 25 Ncm. This was achieved by applying an equivalent preload calculated according to the different friction coefficients chosen. Second, the construction was externally loaded with a force of 200 N inclined by 30 degrees relative to the implant axis. RESULTS The screw preload increased with the decreasing friction coefficient. In all components, stresses increased with decreasing friction coefficient. Plastic deformation was observed at the implant neck in an area that expanded with decreasing friction coefficient. No plastic deformation occurred in the abutment. CONCLUSIONS The results of this study indicated that screw preload should be included in the finite element analysis of dental implants for a realistic evaluation of stresses in the implant-abutment complex. The friction coefficient significantly influenced the screw preload value and modified the stresses in the implant-abutment complex.
منابع مشابه
Influence of Occlusal Forces on Stress Distribution on Preloaded Dental Implant Abutment Screws: A Finite Element Analysis Study
Purpose: The aim of the study is to determine stress distribution on preloaded implant-abutment screws in three different implant systems under simulated occlusal loads. Materials and methods: Three abutments to implant internal hex joint systems were simulated by using the 3-dimensional finite element analysis; (1) Nobel Biocare replace tapered (2) Uniti (3) Lifecare self-threaded tapered ceme...
متن کاملValidation of finite-element simulations with synchrotron radiography – A descriptive study of micromechanics in two-piece dental implants
State-of-the art, two-piece dental implants made from titanium alloys exhibit a complex micromechanical behavior under dynamical load. Its understanding, especially the formation of microgaps, is of crucial importance in order to predict and improve the long-term performance of such implants. Microgap formation in a loaded dental implant with a conical implant-abutment connection can be studied...
متن کاملComparative 3d Fem Analysis of Three Different Dental Implant Shapes
This paper presents the results of numerical modeling using the finite element method of three implants. Geometric models of individual parts of the analyzed system (implant, abutment and screw) and the standard models of the bone and the crown were built in the Ideas NX environment. On the basis of real geometric models the fully three-dimensional numerical models were built. The calculations ...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملStress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis
Background. Screw-retained restorations are favored in some clinical situations such as limited inter-occlusal spaces. This study was designed to compare stresses developed in the peri-implant bone in two different types of screw-retained restorations (segmented vs. non-segmented abutment) using a finite element model. Methods. An implant, 4.1 mm in diameter and 10 mm in length, was placed in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 112 2 شماره
صفحات -
تاریخ انتشار 2014