General Gauge and Conditional Gauge
نویسنده
چکیده
منابع مشابه
Rain Gauge Station Network Design for Hormozgan Province in Iran
A rain gauge network should serve general as well as specific purposes such as water supply, hydropowergeneration, flood forecasting, irrigation, and flood control. The level of accuracy a network can achieve depends onthe number and locations of gauges in the network. In this study, a rain gauge network was designed for Hormozganprovince in the south of Iran. Monthly rainfall totals from 124 r...
متن کاملComparison of Inferior Dental Nerve Block Injections in Child Patients Using 30-Gauge and 27-Gauge Short Needles
Introduction: The purpose of the present study was to record their pain sensation and to assess children`s reaction objectively and subjectively while receiving dental local anesthesia with 27- and 30-gauge needles. Methods: Forty children (24 boys and 16 girls) participated in this study. A random double-blinded crossover design was used so that each child served as his or her own control, rec...
متن کاملDesign and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations
In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...
متن کاملConditional gauge theorem for non - local Feynman - Kac transforms
Feynman-Kac transforms driven by discontinuous additive functionals are studied in this paper for a large class of Markov processes. General gauge and conditional gauge theorems are established for such transforms. Furthermore, the L2-infinitesimal generator of the Schrödinger semigroup given by a non-local Feynman-Kac transform is determined in terms of its associated bilinear form.
متن کاملSimulation of environmental dose distribution of nuclear gauge device MC-1DR by MCNPX code
In this study, distribution of dose rate around the nuclear gauge device MC-1DR which located in shahrekord university was simulated by MCNPX code and was compared whit the measured values. Due to the asymmetry of device and neutron and gamma source positions, the dose rates were determined at a distance of 5, 30 and 100 cm in different directions. Base on the complex geometry of the inside of ...
متن کامل