Preparation, characterization, and performance evaluation of UiO-66 analogues as stationary phase in HPLC for the separation of substituted benzenes and polycyclic aromatic hydrocarbons

نویسندگان

  • Weiwei Zhao
  • Chaoyan Zhang
  • Zengguang Yan
  • Youya Zhou
  • Jianrong Li
  • Yabo Xie
  • Liping Bai
  • Lin Jiang
  • Fasheng Li
چکیده

UiO-66 analogues are good candidates as stationary phase in HPLC because of their chemical/thermal stability, large surface area, and two cage structures. Here, two UiO-66 analogues, UiO-66-NH2 and UiO-67, were synthesized and used as stationary phase in HPLC to evaluate their performance in the separation of substituted benzenes (SBs) and polycyclic aromatic hydrocarbons (PAHs). The results showed that SBs could be well separated on UiO-66-NH2 column but not on UiO-67 column. Nonetheless, PAHs could be well separated on UiO-67 column. The separation mechanisms of SBs and PAHs on UiO-66 analogues may be involved in the pore size and functional group in the frameworks of UiO-66 analogues. Introduction of the-NH2 into UiO-66 significantly reduced its adsorption capacity for SB congeners, which resulted in less separation of SBs on UiO-66-NH2. As for the separation of PAHs on UiO-67 column, the π-π stacking effect was supposed to play a vital role.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SEPARATION OF POLYCYCLIC AROMATIC HYDROCARBONS WITH MIXED MICELLAR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Separation of Polycyclic Aromatic Hydrocarbons was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, types and amounts of coorganic solvent in mobile phase on efficiency, asymmetry factor and selectivity factor showed that the appropriate condition for separation of these compounds was 3% isopropanol (V/V) as co-organic solvent in mobile phase at 40°C. Analysis of...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

Determination of Polycyclic Aromatic Hydrocarbons in Olive and Refined Pomace Olive Oils using HPLC/FLD

ABSTRACT: In this study, an analytical method is developed to determine 15 polycyclic aromatic hydrocarbons (PAHs) in olive and refined pomace olive oils using HPLC coupled with a fluorescence detector. The standardised method of ultrasound-assisted solvent extraction consisted of liquid–liquid extraction with organic solvent and purification on C18 and Florisil bonded-phase cartridges was modi...

متن کامل

The potential of low temperature extraction method for analysis of polycyclic aromatic hydrocarbons in refined olive and refined pomace olive oils by HPLC/FLD

Background and Objectives: A method was developed and validated for determining 15 polycyclic aromatic hydrocarbons (PAHs) in refined olive and refined pomace olive oils using high performance liquid chromatography coupled with a fluorescence detector. Materials and Methods: The sample preparation involved liquid–liquid extraction with organic solvent and low temperature clean-up. The low temp...

متن کامل

Solid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography

Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017