Risk Assessment Method of UHV AC/DC Power System under Serious Disasters
نویسندگان
چکیده
Based on the theory of risk assessment, the risk assessment method for an ultra-high voltage (UHV) AC/DC hybrid power system under severe disaster is studied. Firstly, considering the whole process of cascading failure, a fast failure probability calculation method is proposed, and the whole process risk assessment model is established considering the loss of both fault stage and recovery stage based on Monte Carlo method and BPA software. Secondly, the comprehensive evaluation index system is proposed from the aspects of power system structure, fault state and economic loss, and the quantitative assessment of system risk is carried out by an entropy weight model. Finally, the risk assessment of two UHV planning schemes are carried out and compared, which proves the effectiveness of the research work.
منابع مشابه
A New Power Management Approach for PV-Wind-Fuel Cell Hybrid System in Hybrid AC-DC Microgrid Configuration
The hybrid AC-DC microgrid (HMG) architecture has the merits of both DC and AC coupled structures. Microgrids are subject to intermittence when the renewable sources are used. In the HMG, since power fluctuations occur on both subgrids due to varying load and unpredictable power generation from renewable sources, proper voltage and frequency regulation is the critical issue. This article propos...
متن کاملANOVELMONITORINGTECHNIQUE TO DEFINE CP CRITERIA FOR BURIED PIPELINES UNDER AC CORROSION CONDITION
Abstract: The risks of alternating current (AC) corrosion and overprotection increasingly demand new criteria forcathodically protected pipelines. To assess the risk of AC corrosion, new cathodic protection (CP) criteria have beenproposed based on DC/AC current densities measurements using coupons. The monitoring system designed for thisproject was based on the instant-off method, with steel co...
متن کاملBIC based on Modified Droop Control of Hybrid AC/DC Microgrid with PV/Wind/ESS under Variable Generation and Load Conditions
The idea of a microgrid is created by utilizing more diverse ac or dc distributed generation (DG) sources along with an energy storage system (ESS) and loads. The most efficient and reliable selection of ac and dc microgrids is a hybrid ac/dc microgrid. The hybrid microgrid largely overcomes the shortcomings of standalone ac or dc microgrids. A bidirectional interlinking converter (BIC) is util...
متن کاملOperation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads
This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...
متن کامل-1 MV DC UHV Power Supply for ITER NBI
Abstract. Japan Atomic Energy Agency as the JApan Domestic Agency (JADA) for ITER and the Domestic Agency of EU (EUDA) agreed the procurement sharing for the ITER NBI power supply system. The JADA contributes procurement of dc -1 MV ultra-high voltage (UHV) components such as a -1 MV dc generator, a transmission line and a -1 MV insulating transformer. The dc UHV insulation has been carefully a...
متن کامل