Validation of a freehand 3D ultrasound system for morphological measures of the medial gastrocnemius muscle.

نویسندگان

  • Lee Barber
  • Rod Barrett
  • Glen Lichtwark
چکیده

Muscle volume and length are important parameters for examining the force-generating capabilities of muscle and their evaluation is necessary in studies that investigate muscle morphology and mechanical changes due to age, function, pathology, surgery and training. In this study, we assessed the validity and reliability of in vivo muscle volume and muscle belly length measurement using a multiple sweeps freehand 3D ultrasound (3DUS). The medial gastrocnemius of 10 subjects was scanned at three ankle joint angles (15 degrees , 0 degrees and -15 degrees dorsiflexion) three times using the freehand 3DUS and once on the following day using magnetic resonance imaging (MRI). All freehand 3DUS and MRI images were segmented, volumes rendered and volumes and muscle belly lengths measured. The freehand 3DUS overestimated muscle volume by 1.9+/-9.1 mL, 1.1+/-3.8% difference and underestimated muscle belly length by 3.0+/-5.4mm, 1.3+/-2.2% difference. The intra-class correlation coefficients (ICC) for repeated freehand 3DUS system measures of muscle volume and muscle belly length were greater than 0.99 and 0.98, respectively. The ICCs for the segmentation process reliability for the freehand 3DUS system and MRI for muscle volume were both greater than 0.99 and muscle belly length were 0.97 and 0.99, respectively. Freehand 3DUS is a valid and reliable method for the measurement of human muscle volume and muscle belly length in vivo. It could be used as an alternative to MRI for measuring in vivo muscle morphology and thus allowing the determination of PCSA and estimation of the force-generating capacity of individual muscles within the setting of a biomechanics laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue

The developmental goal of 3D ultrasound imaging (3DUS) is to engineer a modality to perform 3D morphological ultrasound analysis of human muscles. 3DUS images are constructed from calibrated freehand 2D B-mode ultrasound images, which are positioned into a voxel array. Ultrasound (US) imaging allows quantification of muscle size, fascicle length, and angle of pennation. These morphological vari...

متن کامل

Medial gastrocnemius muscle volume in ambulant children with unilateral and bilateral cerebral palsy aged 2 to 9 years.

AIM Calf muscle growth in children with unilateral cerebral palsy (UCP) and bilateral cerebral palsy (BCP) is unknown. This cross-sectional study examines the medial gastrocnemius growth rates of ambulatory children with UCP and BCP compared with children with typical development (CTD), aged 2 to 9 years. METHOD Fifty children with UCP (mean age 66mo [SD 18], 29 males, Gross Motor Function Cl...

متن کامل

Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of the ankle joint and medial gastrocnemius (MG) muscle in young adults with SCP ...

متن کامل

Freehand three‐dimensional ultrasound to assess semitendinosus muscle morphology

In several neurological disorders and muscle injuries, morphological changes of the m. semitendinosus (ST) are presumed to contribute to movement limitations around the knee. Freehand three-dimensional (3D) ultrasound (US), using position tracking of two-dimensional US images to reconstruct a 3D voxel array, can be used to assess muscle morphology in vivo. The aims of this study were: (i) to in...

متن کامل

Reliability of Ultrasound Measures of M. Gastrocnemius Pennation Angle

There are currently few studies in the literature concerning the reliability and validity of the quantification of parameters of muscle architecture using the technique of ultrasound. The aim of this study is to apply the technique of ultrasound imaging to quantify pennation angle of gastrocnemius muscle (medial and lateral) and to determine the reliability and reproducibility of these measures...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 42 9  شماره 

صفحات  -

تاریخ انتشار 2009