Sr/Y and Calibration of Contamination Superficial Monitors at SSDL-ININ-Mexico

نویسنده

  • J. T. Álvarez-Romero
چکیده

In the Metrology Department at ININ, there is a Secondary Standard Dosimetry Laboratory SSDL, since 1987 it has an Alpha-Beta calibration room. In this room there are: the Beta Secondary Standard BSS Nr. 86 with traceability to the primary laboratory Physikalisch-Technische Bundesanstalt PTB and a reference class extrapolation chamber EC, which had been accredited as Mexican National Standard for realizing the unit of absorbed dose rate to air ) 0 ( Dair & for Sr/Y. The developed activities with these standards are: a) Calibration of ophthalmic applicators with the EC for the determination of ; b) Measurement of at the equivalent tissue deep 0,07 mm , for ) 0 ( Dair & ) 07 , 0 ( Dt & Sr/Y sources of the BSS; c) Monte Carlo MC simulations for ) 0 ( Dair & with the Penelope algorithm; d) Construction of control charts of for the BSS of ) 0 ( Dair & Sr/Y, (Shewhart technique); e) Calibration of personnel dosimeters and ionization chambers in terms of: personal dose equivalent Hp(0.07) and directional dose equivalent H’(0.07,α) with the BSS; f) Testing of personnel dosimetry performance for beta particles in terms of shallow dose equivalent HS(0.07) for Laguna Verde Mexican Nuclear Power Plant. Also, the expanded uncertainties U are presented for , in agreement with the BIPM recommendations, and the percent deviations respect to PTB values. In the other hand, the SSDL-ININ (Nuclear Centre of Mexico) is located at 3 000 meters over the sea level, at Salazar town where P≅71,0 kPa, P/T≅ 0,24 kPa K ) 0 ( D air & ; therefore it was necessary to apply the correction factors: kad and kab; the first one, in order to correct the measurements for atmospheric reference conditions T0 y P0, the second one to take account the attenuation and scattering radiation in the external air to EC. However, for SSDL atmospheric conditions this later factor is out to the range of conditions considerate at PTB. That is why we used correction methods with a broad range, mainly: the NIST procedure and others employed for European laboratories. Additionally, the SSDL-ININ had taken in account another correction factor kdis, this to correct the attenuation and scattering radiation in the air inside the EC volume. Finally, the SSDL has been doing calibration services for contamination superficial monitors by the determination of instrument efficiency εi, and for these services, we utilized reference sources calibrated in terms of surface emission rate q2π.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Occurrence of Intestinal Parasites in Fruits and Vegetables from Markets of Northwest Mexico

Background: Fruits and vegetables are potential vehicle of transmission of intestinal parasites. The main aim of this study was to determine prevalence of intestinal parasitic contamination in fruits and vegetables sampled from Caborca region, Northwest Mexico. Methods: A total of 400 fruit and vegetable samples were collected from unregulated open-air markets and closed (i.e., regulated) mark...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Phyllodes Tumor of the Breast: 307 Treated Cases, the Largest Mexican Experience at a Single Breast Disease Institution

Background: Phyllodes tumor (PT) of the breast in Hispanic patients is more frequently reported with large tumors and with more borderline/malignant subtypes compared with other populations. The objective of this study was to describe characteristics of patients with PT and to identify differences among subtypes in a Mexican population.  <...

متن کامل

Application of the thermoluminescent technique for calibration and dosimetry of 90 Sr + 90 Y applicators

Dermatological and ophthalmic applicators are used in brachytherapy for the treatment of superficial lesions of skin and eyes. The calibration of these applicators should be realized periodically, according to quality control programs and international recommendations about dosimetry and calibration of brachytherapy sources. Thin thermoluminescent dosimeters of CaSO4:Dy were utilized in this wo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004