Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents

نویسندگان

  • Matthias Sigler
  • Julia Klötzer
  • Thomas Quentin
  • Thomas Paul
  • Oliver Möller
چکیده

BACKGROUND Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. METHODS Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. RESULTS On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. CONCLUSIONS After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

منابع مشابه

Venous drug-eluting vs. bare-metal stenting: an experimental animal study using frequency domain optical coherence tomography.

INTRODUCTION This protocol was designed to evaluate the safety and feasibility of implanting drug-eluting stents (DES), as well as to compare their long-term results versus bare-metal stents (BMS), in a rabbit venous model, using frequency-domain optical coherence tomography (FD-OCT). METHODS Thirteen New Zealand white rabbits underwent implantation of a zotarolimus-eluting stent in the iliac...

متن کامل

Evaluation of the haemodynamic characteristics of drug-eluting stents at implantation and at follow-up.

AIMS The aim of this study was to investigate the physiologic parameters: fractional flow reserve (FFR), hyperaemic trans-stent gradient (HTG), and wall shear stress (WSS) at implantation and at 6-month follow-up in the drug-eluting sirolimus stent and in its bare metal counterpart implanted in pairs within the same patient. METHODS AND RESULTS Twenty patients, accepted for percutaneous coron...

متن کامل

Bare Metal Stent Thrombosis and In-Stent Neoatherosclerosis

Very late stent thrombosis occurs in patients with bare metal stent implantation, although the annual incidence is much lower than that after drug-eluting stent implantation. In-stent neoatherosclerosis with ruptured plaques and thin-cap fibroatheromas has been observed in bare metal stents. Atherosclerotic plaques harvested from patients with very late stent thrombosis and those with acute cor...

متن کامل

Interventional Cardiology Risk of Elective Major Noncardiac Surgery After Coronary Stent Insertion A Population-Based Study

Background—Guidelines recommend that noncardiac surgery be delayed until 30 to 45 days after bare-metal stent implantation and 1 year after drug-eluting stent implantation. Methods and Results—We used linked registry data and population-based administrative health care databases to conduct a cohort study of 8116 patients (Ն40 years of age) who underwent major elective noncardiac surgery in Onta...

متن کامل

Impact of Heterogeneous Overlapping Drug-Eluting Stents on the Arterial Responses of Rabbit Iliac Arteries: A Comparison With Overlapping Bare Metal Stents

BACKGROUND AND OBJECTIVES Although the use of heterogeneous overlapping drug-eluting stents (DES) is not uncommon in clinical practice, whether the implantation sequences of heterogeneous DES will influence the endothelialization or arterial responses differently remains unclear. MATERIALS AND METHODS Twenty-one rabbits were randomized to receive overlapping stents in the iliac artery for 3 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015