The effects of conventional extracorporeal circulation versus miniaturized extracorporeal circulation on microcirculation during cardiopulmonary bypass-assisted coronary artery bypass graft surgery.
نویسندگان
چکیده
OBJECTIVES To reduce the complications associated with cardiopulmonary bypass (CPB) during cardiac surgery, many modifications have been made to conventional extracorporeal circulation systems. This trend has led to the development of miniaturized extracorporeal circulation systems. Cardiac surgery using conventional extracorporeal circulation systems has been associated with significantly reduced microcirculatory perfusion, but it remains unknown whether this could be prevented by an mECC system. Here, we aimed to test the hypothesis that microcirculatory perfusion decreases with the use of a conventional extracorporeal circulation system and would be preserved with the use of an miniaturized extracorporeal circulation system. METHODS Microcirculatory density and perfusion were assessed using sublingual side stream dark-field imaging in patients undergoing on-pump coronary artery bypass graft (CABG) surgery before, during and after the use of either a conventional extracorporeal circulation system (n = 10) or a miniaturized extracorporeal circulation system (n = 10). In addition, plasma neutrophil gelatinase-associated lipocalin and creatinine levels and creatinine clearance were assessed up to 5 days post-surgery to monitor renal function. RESULTS At the end of the CPB, one patient in the miniaturized extracorporeal circulation-treated group and five patients in the conventional extracorporeal circulation-treated group received one bag of packed red blood cells (300 ml). During the CPB, the haematocrit and haemoglobin levels were slightly higher in the miniaturized extracorporeal circulation-treated patients compared with the conventional extracorporeal circulation-treated patients (27.7 ± 3.3 vs 24.7 ± 2.0%; P = 0.03; and 6.42 ± 0.75 vs 5.41 ± 0.64 mmol/l; P < 0.01). The density of perfused vessels with a diameter <25 µm (i.e. perfused vessel density) decreased slightly in the conventional extracorporeal circulation-treated group from 16.4 ± 3.8 to 12.8 ± 3.3 mm/mm(2) (P < 0.01) and remained stable in the miniaturized extracorporeal circulation-treated group (16.3 ± 2.7 and 15.2 ± 2.9 mm/mm(2) before and during the pump, respectively). Plasma neutrophil gelatinase-associated lipocalin levels were increased following the use of extracorporeal circulation in both groups, and no differences were observed between the groups. Plasma creatinine levels and creatinine clearance were not affected by CABG surgery or CPB. CONCLUSIONS The results from this relatively small study suggest that the use of the miniaturized extracorporeal circulation system is associated with a statistically significant (but clinically insignificant) reduction in haemodilution and microcirculatory hypoperfusion compared with the use of the conventional extracorporeal circulation system.
منابع مشابه
Bilateral Extracorporeal Circulation ("Drew Technique") for Coronary Artery Bypass Surgery using Patient's Lung as Oxygenator
The aim of this study was to determine: 1) whether a bilateral perfusion circuit (Drew technique) using the patient's own lung as the oxygenator is feasible for multi-vessel coronary artery bypass grafting; and 2) if the systemic inflammatory response to extracorporeal circulation differs compared to conventional cardiopulmonary bypass procedures. Twenty patients were enrolled in a randomized, ...
متن کاملEconomic analysis of coronary artery bypass grafting with minimal versus conventional extracorporeal circulation
Background This study aims to develop a methodological framework for the comparative economic evaluation between Minimal Extracorporeal Circulation (MECC) versus conventional Extracorporeal Circulation (CECC) in patients undergoing coronary artery bypass grafting (CABG) in different healthcare systems. In addition, the scope is to evaluate the cost-effectiveness ratio of alternative comparators...
متن کاملAdvantages to Miniaturized Cardiopulmonary Bypass for Adult Cardiac Surgery
The development of cardiopulmonary bypass (CPB) and open heart surgery in the 1950s has benefited millions of people around the world over the last half century. However, it has been recognized since the beginning that there are detrimental effects to CPB. In an effort to minimize the effects of CPB, a miniaturized CPB (M-CPB) closed circuit system also known as closed circuit extracorporeal ci...
متن کاملEffect of closed minimized cardiopulmonary bypass on cerebral tissue oxygenation and microembolization.
OBJECTIVE Coronary artery bypass grafting with cardiopulmonary bypass carries a risk for neurologic complications because of cerebral hypoperfusion and microembolization. The basic goals of a novel closed minimized extracorporeal circulation are to prevent excessive hemodilution and to avoid blood-air interface. The aim of this prospective randomized study was to determine the effect of using t...
متن کاملComparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries
Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2012