Allocating harmonic emission to MV customers in long feeder systems

نویسنده

  • V. J. Gosbell
چکیده

Previous work has attempted to find satisfactory methods for the allocation of harmonic current emission MV subsystems containing long feeders. It has been proposed that best use of the network's harmonic absorption capacity is made if the allocated current varies with the inverse square root of the harmonic impedance at the point of connection. It has been shown that an exact solution following this principle requires an impracticably large amount of data. Here it is assumed that each feeder supplied from a given substation has its load distributed uniformly and continuously along it, giving equations requiring only a modest amount of data. It is demonstrated by means of a suitable example that the method is sufficiently accurate for practical situations where loads are lumped non-uniformly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solving Harmonic Resonance Problems on the Medium Voltage System

Harmonic problems are increasing on MV systems, especially with the application of power factor correction capacitors or extensive underground networks that resulting resonances close to the fifth harmonic. This paper describes two case studies of solving harmonic resonance problems on distribution systems with the design of harmonic filters that provide both power factor correction and harmoni...

متن کامل

A New Method to Study Aggregation Effect of Harmonic Current Emissions in a Wind Farm Based on Type-III Wind Turbine Average Modeling

Assessment of complex harmonic current contribution of each wind turbines at connection point of a wind farm to the grid (primary emission) is presented in this paper. Moreover, contribution of grid background harmonic voltage distortion on harmonic current distortion (secondary emission) of each turbine is also evaluated. Both assessments are represented based on primary and secondary transfer...

متن کامل

Dynamic Harmonic Analysis of Long Term over Voltages Based on Time Varying Fourier series in Extended Harmonic Domain

Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs an Extended Harmonic Domain (EHD) based framework for dynamic analysis of long term analysis over voltages during the tra...

متن کامل

Electrical Load Manageability Factor analyses by Artificial Neural Network Training

On typical medium voltage feeder, Load side management means power energy consumption controlling at connected loads. Each load has various amount of reaction to essential parameters variation that collection of these reactions is mentioned feeder behavior to each parameter variation. Temperature, humidity, and energy pricing variation or major event happening and power utility announcing to th...

متن کامل

Load Balancing Using a Best-Path-Updating Information-Guided Ant Colony Optimization Algorithm

Abstract: Load balancing and phase balancing are important complement to reconfiguration of the feeder and the network.In the distribution automation ,these issues must be solved continuously and simultaneously to ensure the optimal performance of a distribution network.Distribution network imbalance has various consequences such as increase in power losses, voltage drop,cost increase,etc.In th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003