Relation between transcardiac and transthoracic current during defibrillation in humans.
نویسندگان
چکیده
Conceptually, transthoracic defibrillation threshold current can be considered a function of at least two quantities. It is directly proportional to the transcardiac threshold current and inversely proportional to the transcardiac current fraction (FC) or the ratio of transcardiac and transthoracic current. Although experimental and theoretical estimates of FC have been as high as 45%, previous measurements in humans have not been made. This study was designed to quantify FC in humans. During intraoperative testing of the automatic implantable cardioverter defibrillator, transthoracic rescue shocks of 200-400 J were delivered when the device failed to defibrillate. Simultaneous transthoracic voltage (VT) and transcardiac voltage (VC) between two implanted epicardial patch electrodes were measured. The ratio, VC/VT, was 0.04 +/- 0.03 (mean +/- SD) in 10 patients. In 16 dogs, a comparison was made between direct measurement of FC and VC/VT. FC was determined with a specially designed electrode system, which was calibrated to account for field distortion introduced by the electrodes. There was no significant difference between FC and VC/VT, which were both approximately 0.05, suggesting that VC/VT was statistically equivalent to FC. The results of this study, therefore, indicate that during transthoracic defibrillation in humans, approximately 4% of transthoracic current traverses the heart. This relatively small percentage of current results from the existence of parallel pathways, such as the thoracic cage and lungs, which shunt current around the heart.
منابع مشابه
Intrathoracic current flow during transthoracic defibrillation in dogs. Transcardiac current fraction.
To achieve transcardiac threshold current during transthoracic defibrillation, a considerably larger current must be delivered to the thorax to compensate for the shunting effect of the lungs, the thoracic cage, and other elements of the torso. This shunting effect is thus an important determinant of transthoracic defibrillation threshold and can be quantified by the transcardiac current fracti...
متن کاملRise in defibrillation threshold after postoperative cardiac remodeling in a patient with severe Ebstein’s anomaly
Introduction Implantable cardioverter-defibrillators (ICDs) are considered standard of care for patients with life-threatening cardiac arrhythmias. In small children and patients with venous anatomy that prohibits placement of traditional transvenous leads, nontransvenous coil positions have been used and can be characterized as epicardial, pleural, subcutaneous, or a hybrid of any of the 3 pos...
متن کاملdefibrillation: experimental studies
In defibrillation, current flow depends on the energy selected and the transthoracic impedance. If transthoracic impedance is high, current flow may be inadequate to defibrillate. We developed a method by which high transthoracic impedance is automatically compensated for by an increase in operator-selected energy when impedance is high. Transthoracic impedance was predicted in advance of the f...
متن کاملEffects of positive end-expiratory pressure on transthoracic impedance--implications for defibrillation.
The success of defibrillation is determined by trans-myocardial current. This current is inversely proportional to transthoracic impedance (TTI). We proposed that increasing lung volume using positive end-expiratory pressure (PEEP) would increase TTI. 12 healthy subjects aged 21-37 years (6 male) were recruited. TTI between self-adhesive defibrillation pads placed in the standard antero-apical ...
متن کاملBRIEF REVIEW Determinants of successful defibrillation
Ventricular defibrillation by electric counter shock is the definitive treatment for cardiac arrest due to ventricular fibrillation (VF). Ventricular defibrillation is the fundamental cornerstone to a successful outcome. As most deaths from VF occur out of hospital, often in patients without pre-existent recognised cardiac disease, the major public health issue remains the widespread applicatio...