Comparison of the KonRad IMRT and XiO treatment planning systems
نویسندگان
چکیده
Reducing the treatment time for IMRT patients is highly desirable. The objective of this work was to evaluate the new clinical Siemens KonRad inverse treatment planning system (TPS) and compare it to the CMS XiO TPS with special emphasis on the segmentation efficiency. For head and neck, liver and prostate cancer patients, step-and-shoot IMRT plans were designed using both CMS XiO and Siemens KonRad TPS. Number, direction and energy of beams used were the same in the plans from both systems for each treatment site. The plans were optimized to achieve the same clinical objectives concerning dose to the target volume and to the relevant organs-at-risk (OARs). The number of intensity levels were minimized until the clinical objectives could not be achieved anymore. Dose-volume histograms (DVHs), mean- and maximum-doses were compared, as well as the number of beam segments and monitor units (MUs). The beams of each plan were delivered individually on a MapCheck device to verify the agreement between calculations and measurements to be less than 3%-3 mm distance-to-agreement. Plans optimized with KonRad resulted in fewer segments and lower number of MUs and therefore reduced delivery time on average by 20%, while achieving similar dose distributions. CMS XiO plans exhibited a slightly steeper dose fall-off outside the target volumes; however the difference was not clinically significant. DVHs to OARs were comparable. All calculated dose distributions passed the 3%-3 mm verification check.
منابع مشابه
A comparison of three commercial IMRT treatment planning systems for selected pediatric cases
This work aimed at evaluating the performance of three different intensity-modulated radiotherapy (IMRT) treatment planning systems (TPSs)--KonRad, XiO and Prowess--for selected pediatric cases. For this study, 11 pediatric patients with different types of brain, orbit, head and neck cancer were selected. Clinical step-and-shoot IMRT treatment plans were designed for delivery on a Siemens ONCOR...
متن کاملDose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
متن کاملGAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119
The purpose of this work was to perform a comprehensive comparison of static field intensity modulated radiation therapy (IMRT) for patient specific quality assurance (QA) in order to investigate commissioning of a XiO treatment planning system (TPS). QA measurements were evaluated for three of four test geometries provided in American Association of Physicists in Medicine (AAPM) Task Group Rep...
متن کاملPyCMSXiO: an external interface to script treatment plans for the Elekta® CMS XiO treatment planning system
Scripting in radiotherapy treatment planning systems not only simplifies routine planning tasks but can also be used for clinical research. Treatment planning scripting can only be utilized in a system that has a built-in scripting interface. Among the commercially available treatment planning systems, Pinnacle (Philips) and Raystation (Raysearch Lab.) have inherent scripting functionality. CMS...
متن کاملAssessment of out-of-field dose calculation algorithm by commercial treatment planning systems in IMRT and 3DCRT
Abstract Introduction: The accuracy an assessment of out- of- field dose due to secondary cancer risk is clinically important. Actually radiotherapy treatment planning systems are not commissioned for the out-of-field dose calculations, so the estimation of dose distributions by TPSs beyond the borders of treatment fields is not well calculate...
متن کامل