Assessing mechanical deformations in two-winding transformer unit using reduced-order circuit model

نویسندگان

  • Krupa Rajendra Shah
  • K. Ragavan
چکیده

Certain level of mechanical deformations in winding does not hamper the normal performance of power transformer. However, such incipient deformations if unattended could result in permanent failure of transformer. To this end, an approach is proposed to assess the severity of mechanical deformations in transformer winding. These deformations get reflected as changes in its high frequency behaviour. Hence, characterising the high frequency behaviour is essential. This requires building physically realisable ladder circuit corresponding to each winding. Thus, n-winding transformer is represented by n electrically and magnetically coupled ladder networks. In such scenario, the objective of fault diagnostics becomes very challenging. In this effort, realising the multi-winding unit by reduced-order ladder circuit model is explored. This approach essentially involves energising one winding at a time. Then, reducedorder ladder circuit of considered unit is synthesised from its measured driving-point impedance data. It is shown how these circuit models could be used for identifying mechanical deformations. To demonstrate capability of the method, two-winding model transformer is considered and deformations are introduced in its outer winding. Then, reduced-order circuit models are synthesised corresponding to healthy and faulty state of model transformer. The location of fault is identified by the changed parameter in the circuit. Further, the amount of change reveals the severity of introduced deformation. In all the cases, synthesised reduced-order circuit model agrees with that of model transformer with regard to driving-point impedance plot and results are found satisfactory. 2016 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Power Auto-transformer Mechanical Faults Diagnosis ‎Using Finite Element based FRA

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

متن کامل

FEM based Reactance Computation for Transformer Winding Deformation Detection

Leakage reactance is one of the most important specifications in transformer that has significant impact on its overall design. Variation in leakage reactance serves as a diagnostic measure to indicate mechanical integrity of power transformers before and after a short circuit test that demonstrates mechanical strength of transformer windings. This paper presents an approach for leakage reactan...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016