Assessment of global left ventricular systolic function with multidetector CT and 2D echocardiography: a comparison between reconstructions of 1-mm and 2-mm slice thickness at multidetector CT.
نویسندگان
چکیده
PURPOSE To compare multidetector computed tomography (MDCT) and two-dimensional transthoracic echocardiography (2DE) for left ventricular ejection fraction (EF); and to make comparison between reconstructions of 1-mm and 2-mm slice thickness at MDCT in left ventricular analysis by using a semiautomated segmentation algorithm. MATERIALS AND METHODS In 43 patients global left ventricular systolic function was assessed by using both MDCT and 2DE. Functional MDCT data sets were reconstructed in 20 cardiac phases (0-95%) with both 1-mm and 2-mm slice thickness.With semi-automatic left ventricle segmentation, end-diastolic volume (EDV), endsystolic volume (ESV) and EF were calculated seperately for both 1-mm and 2-mm reconstructions. RESULTS On MDCT with 1-mm slice thickness, mean EF was 66.8 +/- 5.6 %, mean EDV was 133.7 +/- 38.9 mL, and mean ESV was 45.1 +/- 17.9 mL, these values for 2-mm slice thickness were 66.2 +/- 5.6 %, 133.5 +/- 39.6 mL, and 45.9 +/- 18.3 mL, respectively. On 2DE, mean EF was 66.7 +/- 5.7 %, mean EDV was 98.7 +/- 42.1 mL, and mean ESV was 33.6 +/- 18.7 mL. There was no difference between EF values calculated with 1-mm and 2-mm reconstructions and 2DE (P = 0.83 and P = 0.3705, respectively). However, EDV and ESV values calculated by MDCT were significantly higher than those obtained by 2DE (P < 0.0001). CONCLUSION There was a good correlation between MDCT and 2DE in the evaluation of left ventricular EF. At MDCT left ventricular ESV was statistically smaller, EF was statistically greater by using 1-mm rather than 2-mm slice thickness. However, these differences are not clinically relevant.
منابع مشابه
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملGlobal and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance.
AIMS To compare multidetector row computed tomography (MDCT) global and regional left ventricular (LV) function assessment with echocardiography and cardiovascular magnetic resonance (CMR). METHODS AND RESULTS In 25 patients, who were referred for noninvasive angiography with 16-detector row CT, LV function assessment was also performed. A subsequent echocardiogram was performed, and in a sub...
متن کاملInvestigation of Morphology of the Hyoid Bone According to Age and Gender With Multidetector Computarized Tomography
Introduction: In our study, we aimed 200 cases were evaluated for the length, width and angle of hyoid bone and its distance from certain anatomical structures. Methods: This study was perfomed retrospectively in 2010 - 2013 on 200 CT images. 3D volume rendering images of pure hyoid bone were created from the axial CT images in 1 mm slice thickness. In our study, 200 cases (94 female, 106 male...
متن کاملAssessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography
BACKGROUND Multidetector computed tomography (MDCT) has been demonstrated as a feasible imaging modality for noninvasive assessment of coronary artery disease and left ventricular (LV) function. Recently, 320-row systems have become available with 16 cm anatomical coverage allowing image acquisition of the entire heart within a single heartbeat. The purpose of this study was to evaluate the acc...
متن کاملDysglycemia and cardiovascular risk.
1. Hoffmann R, von Bardeleben S, Kasprzak JD, et al. Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods. J Am Coll Cardiol 2006; 47:121–8. 2. Hoffmann R, von Bardeleben S, ten Cate F, et al. Assessment of systolic left ventricular function: a multi-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diagnostic and interventional radiology
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2010