Re. Calibration of peak expiratory flow (PEF) measuring devices.
نویسنده
چکیده
There are increasing numbers of devices coming onto the market for measuring PEP and of papers assessing their performance. In these papers a number of different ways of calibrating the devices have been used, as discussed in your correspondence columns [1]. What is the best way to calibrate a peak flow (PP) meter for clinical use? It seems not to be realized that compared with a large pneumotachometer, portable PP meters have an appreciable resistance to airflow. This will have a measurable effect on the very thing being measured, i.e. the PEP. When WRimrr and McKEiutow [2J calibrated their original instrument in 1959 they used a form of calibration which allowed for this. Having calibrated a large low resistance pneumotachometer with calibrated rotameters and steady flows, they had their subjects make alternate blows through the pneumotachometer and the PP meter. The resulting calibration gave PEP readings which were the flows that would have resulted had the meter had the resistance of the pneumotachometer, not the actual flow through the meter. This, of course, is what the clinician wants. Using this form of calibration any other instrument should give similar results in the same subject. Actually, the original Wright meter did not have a very high resistance, so that the difference between its calibration and absolute was small. The mini Wright PP meter has a resistance about three times as great and so it is not surprising that when calibrated in absolute flows it is found to over-read slightly [3). Other devices with higher resistances will be more affected. This does not matter since the "error" seems to be systematic and can be allowed for providing the calibration is of the type described above. The drawback of this method is that the blows into the two instruments (pneumatachometer and PP meter) will not be identical. However, by using a large number of blows this "noise" can be largely eliminated. The purist approach might be to calibrate meters in absolute terms, using for instance the method of SHAPIRO et a/.[3]. Subjects blow through a pneumotachometer in line with the meter, having calibrated it first with the meter in place. It would then be necessary to work out and apply some correction factor unique to that meter to increase the result to that which would have been obtained on a low resistance pneumotachometer. However, this is clearly unnecessarily cumbersome for clinical use. It is being suggested that in future PP meters and electronic spirometers should be calibrated by computer-controlled piston devices designed to deliver artificial forced expirations having flow/volume loops similar to human subjects and patients. This would seem, at first sight, an ideal method of calibration and standardization. However, apart from formidable problems of turbulence at high flows, since these machines will be designed to deliver their standard forced expirations, regardless of the resistance of the device being calibrated, they will not simulate the human lungs in this respect and devices calibrated in this way will not have the correction for resistance built into their calibration. It would seem better to continue to use the less elegant but clinically more useful method of WRIOHT and McKERRow [2], or having calibrated a standard Wright meter by their method to use that as a secondary standard against which to calibrate newer meters.
منابع مشابه
Peak expiratory flow (PEF) monitoring.
T he Wright peak expiratory flow meter was introduced in 1959 and provided a portable piece of equipment for assessing some aspects of lung function in the ambulatory care setting. The original device has been supplanted by the mini Wright peak flow meter (and a range of other devices) which have become relatively cheap but are reasonably reliable for home monitoring. So, with an available devi...
متن کاملThe effect of patient technique and training on the accuracy of self-recorded peak expiratory flow.
The aim of the study was to investigate the difference between encouraged self-recorded peak expiratory flow (PEF) with unobserved readings and to investigate any long-term changes in PEF self-recording. Patients were trained in the PEF technique and asked to keep 2-hourly PEF records until the next clinic visit. The patients PEF were then rechecked at the second clinic visit by a series of two...
متن کاملAssessment of accuracy and applicability of a new electronic peak flow meter and asthma monitor.
The aim of this study was to assess the accuracy and applicability of a portable electronic peak flow meter combined with an asthma monitor (AM1, Jaeger, Germany) which measures peak expiratory flow (PEF), forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). The technical accuracy in PEF, FEV1 and FVC measurement was tested according to American Thoracic Society (ATS) ...
متن کاملPortable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.
Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the ...
متن کاملPeak expiratory flow at increased barometric pressure: comparison of peak flow meters and volumetric spirometer.
Increasing numbers of patients are receiving hyperbaric oxygen therapy as an intensive care treatment, some of whom have pre-existing airway obstruction. Spirometers are the ideal instruments for measuring airway obstruction, but peak flow meters are useful and versatile devices. The behaviour of both types of device was therefore studied in a hyperbaric unit under conditions of increased press...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 4 9 شماره
صفحات -
تاریخ انتشار 1991