Charge carrier and exciton dynamics in LaBr3:Ce scintillators: Experiment and model

نویسنده

  • P. Dorenbos
چکیده

The scintillation yield and decay time of LaBr3 doped with 0.2%, 0.5%, and 5% cerium were studied between 80 K and 600 K. LaBr3 :5%Ce 3+ on a photomultiplier tube shows at 300 K a very high scintillation yield of 22 800 photoelectrons per MeV 64 000 photons per MeV with a decay time of 16 ns. At 600 K the yield decreases by 15%. The scintillation yield of LaBr3 :0.2%Ce3+ is 19 800 photoelectrons per MeV 56 000 photons per MeV at 300 K with a decrease by 50% at 600 K and a main scintillation decay time around 30 ns. The appearance of slow components in the Ce emission indicates a relatively slow energy transfer from the host crystal to Ce. The presence or absence of slow components depends on both concentration and temperature. The results are analyzed and interpreted with a model that comprises prompt charge carrier trapping by Ce and delayed excitation of Ce by means of thermally activated transport of self-trapped exciton defects. The results of the study provide detailed information on the scintillation mechanism. Besides presenting experimental data, the different energy transfer processes are quantified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of LaBr3: Ce and LaCl3: Ce scintillators for spect imaging

This study aims to investigate the potential use of LaBr3:Ce and LaCl3:Ce materials in SPECT imaging. GATE Monte Carlo simulations of single-head gamma camera and a Tc point source were performed to evaluate the energy spectra, modulation transfer function (MTF) and detection efficiency. A range of Ce concentrations (0.5, 5, 10 and 15)% of LaBr3:Ce and LaCl3:Ce crystals was simulated in conjunc...

متن کامل

Pulse-shape discrimination of La halide scintillators

The bright scintillators LaCl3:Ce and LaBr3:Ce were tested for a–g pulse-shape discrimination (PSD). PSD is demonstrated for LaCl3:Ce but not for LaBr3:Ce: r 2005 Elsevier B.V. All rights reserved.

متن کامل

Feasibility study on signal separation for spontaneous alpha decay in LaBr3: Ce scintillator by signal peak-to-charge discrimination.

A novel analysis method named peak-to-charge ratio (V(p)/Q(total)) discrimination, aiming at background rejection especially for alpha decay self-activity in LaBr3: Ce scintillators has been developed. This method is based on a waveform analysis using the peak-to-charge ratio in the output waveform of a photomultiplier tube. The discrimination of alpha-induced events was achieved by using a thr...

متن کامل

Response of LaBr3(Ce) scintillators to 2.5 MeV fusion neutrons.

Measurements of the response of LaBr3(Ce) to 2.5 MeV neutrons have been carried out at the Frascati Neutron Generator and at tokamak facilities with deuterium plasmas. The observed spectrum has been interpreted by means of a Monte Carlo model. It is found that the main contributor to the measured response is neutron inelastic scattering on (79)Br, (81)Br, and (139)La. An extrapolation of the co...

متن کامل

Nonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiation.

The nonproportional scintillation response of LaBr(3) doped with 5% Ce(3+) and of LaCl(3) doped with 10% Ce(3+) was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely spaced energy values between 9 and 100 keV were measured. The experiment was carried out at the X-1 beamline at the Hamburger Synhrotronstrahlungslabor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007