Contrast transcranial doppler ultrasound in the detection of right-to-left shunts : time window and threshold in microbubble numbers.

نویسندگان

  • D W Droste
  • K Silling
  • J Stypmann
  • M Grude
  • V Kemény
  • T Wichter
  • K Kühne
  • E B Ringelstein
چکیده

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of contrast agents and a Valsalva maneuver (VM) as provocation procedure. Currently, data on the appropriate timing of the VM, the use of a diagnostic time window, and a threshold in contrast agent microbubbles detected are insufficient. METHODS Fifty-eight patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with injections of 10 mL of the commercial galactose-based contrast agent Echovist was applied in a randomized way: (1) no VM, (2) VM for 5 seconds starting 2 seconds after the beginning of contrast injection, (3) VM for 5 seconds starting 5 seconds after the beginning of contrast injection, (4) VM for 5 seconds starting 8 seconds after the beginning of contrast injection, and (5) repetitive short VMs in between 2 and 13 seconds after the beginning of contrast injection. In addition to the single tests, we also tested the sensitivity and specificity of combined results of the tests with VM. RESULTS In 21 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-one patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 16 patients were only positive on at least 1 TCD investigation but negative during TEE. Test 3 was the most appropriate test when combined with the results of 1 of the other tests with VM. The highest sensitivities were achieved with a diagnostic time window of 40 seconds and when the presence of a single microbubble was sufficient for the diagnosis of a shunt. CONCLUSIONS TCD performed twice with 2 provocation maneuvers with Echovist is a sensitive method to identify TEE-proven cardiac right-to-left shunts. The VM should be performed for 5 seconds starting at 5 seconds after the beginning of contrast injection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents.

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and different provocation procedures. Currently, data on an appropriate time window for the appearance of contrast bubbles in the TCD recording after the injection of the contrast medium and the com...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli.

BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...

متن کامل

Contrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts

Background and Purpose—Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2000