Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard.

نویسندگان

  • Peter A Woerdeman
  • David D Cochrane
چکیده

Authors of this report describe 2 patients who had undergone shunt insertion for hydrocephalus and who, at 6 weeks or 9 months after their last revision, presented with symptoms of shunt dysfunction and CSF collections at the valve site. At the ensuing shunt revision in both patients, the silicone housing was fractured and the Siphonguard was disconnected from the Codman Hakim Precision flat-bottom valve. The cause of these failures was not clear since manipulation, bending, and twisting of the valves were not thought to have occurred during implantation. A review of the FDA's Manufacturer and User Facility Device Experience (MAUDE) database revealed 58 cases of silicone housing failure in the Codman Hakim Precision valve with integrated Siphonguard since the year 2000. A single report was found in the databases administered by the Canadian Medical Devices Sentinel Network (CMDSNet). The Codman Hakim Precision valves with integrated Siphonguard are delicate devices that do not withstand the intraoperative handling tolerated by other valves. When these valves are implanted, gentle handling and wide exposures are needed to minimize the risk of valve damage. Valves should be handled according to the manufacturer's instructions. However, in light of this particular pattern of failure, it is recommended that the manufacturer redesign this valve to provide handling tolerance that is characteristic of other valves on the market. The featured cases illustrate the importance of the surgeon's role in postmarket surveillance of medical devices and reporting device failures to the responsible agencies and manufacturers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 1-year outcomes for the Chhabra and Codman-Hakim Micro Precision shunt systems in Uganda: a prospective study in 195 children.

OBJECT The author investigated the 1-year outcomes for shunt treatment of hydrocephalic children in Uganda, comparing the results using the inexpensive Chhabra shunt ($35 US dollars), widely used in East Africa, with those using the Codman-Hakim Micro Precision Valve shunt ($650). METHODS The results in 195 consecutive children (mostly infants) in whom shunts were placed were studied prospect...

متن کامل

Improved outcome in shunted iNPH with a combination of a Codman Hakim programmable valve and an Aesculap-Miethke ShuntAssistant.

INTRODUCTION Low pressure valves with ventriculoperitoneal shunts have been proven to lead to good outcomes in the treatment of idiopathic normal pressure hydrocephalus. However, overdrainage complications are often seen with low opening pressures. Efforts have been made to obtain good outcomes without overdrainage complications by decreasing the hydrostatic pressure component using special val...

متن کامل

Alteration of the pressure setting of a Codman-Hakim programmable valve by a television.

A 7-year-old girl presented in semicomatose condition. She had received a ventriculoperitoneal shunt using a Codman-Hakim programmable valve. Head computed tomography demonstrated hydrocephalus and head radiography showed that the pressure setting of the shunt valve had changed to 60 mmH(2)O from 40 mmH(2)O. The pressure setting was returned to 40 mmH(2)O, and she was discharged because her cli...

متن کامل

Magnetically programmable shunt valve: MRI at 3-Tesla.

A magnetically programmable cerebrospinal fluid (CSF) shunt valve (Codman Hakim Programmable Valve, Codman, a Johnson & Johnson Company, Raynham, MA) was assessed for magnetic field interactions, heating, artifacts and functional changes at 3-Tesla. The programmable valve showed minor magnetic field interactions and heating (+0.4 degrees C). Artifacts were relatively large in relation to the si...

متن کامل

Shunt Overdrainage Caused by Displacement of the Pressure Control Cam after Pressure Adjustment

Although the Codman-Hakim programmable valve is one of most popular shunt systems used in the clinical practice for the treatment of hydrocephalus, malfunctions related with this system have been also reported which lead to underdrainage or overdrainage of the cerebrospinal fluid. While obstruction of the ventricular catheter by tissue materials or hematoma and catheter disconnection are relati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery. Pediatrics

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2014