Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period?
نویسندگان
چکیده
New disposable electrodes, the PSArray and XP sensor, have been developed for the patient state analyzer (PSA) and the bispectral index (BIS) monitors, respectively. We designed this clinical study to compare the sensitivity and specificity of the patient state index (PSI) with the BIS during the perioperative period when the new electrode sensors were used. Twenty-two consenting patients scheduled for elective laparoscopic procedures were enrolled in this prospective study. The elapsed time to apply electrodes and obtain a baseline index value was recorded, as were the comparative PSI and BIS values at specific time intervals during the induction, maintenance, and emergence periods in patients who were administered a standardized general anesthetic. In addition, the changes in these indices were recorded after a bolus dose of propofol (20 mg IV) or a 2% increase or decrease in the inspired concentration of desflurane during the maintenance period. The total elapsed time to obtain an index value was similar with both devices (66 +/- 32 s versus 72 +/- 41 s for the PSA and BIS, respectively). By using logistic regression models, both the BIS and PSI were found to be equally effective as predictors of unconsciousness (i.e., failure to respond to verbal stimuli). The PSI also correlated with the BIS during both the induction of (R = 0.85) and the emergence from (R = 0.74) general anesthesia. The area under the receiver operating characteristic curve for detection of consciousness also indicated a similar performance with the PSI (0.98 +/- 0.05) and the BIS (0.97 +/- 0.05). During the maintenance period, the PSI values tended to be lower than the BIS value; however, the responses to changes in propofol and desflurane were similar. Finally, the PSI (versus BIS) values showed less interference from the electrocautery unit during the operation (31% versus 73%, respectively). Although the list price of the PSArray(2) disposable electrode strip (USD $24.95) was higher than that of the BIS XP sensor (USD $17.50), the average sale price (USD $14.95) was identical for both electrode systems. Therefore, we conclude that the PSA monitor with the PSArray(2) is a cost-effective alternative to the BIS monitor with the XP sensor for evaluating consciousness during the induction of and emergence from general anesthesia, as well as for titrating propofol and desflurane during the maintenance period.
منابع مشابه
تاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرامبخش: یک مطالعه آیندهنگر
Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...
متن کاملAssessment of Anesthesia Depth Using Effective Brain Connectivity Based on Transfer Entropy on EEG Signal
Introduction: Ensuring an adequate Depth of Anesthesia (DOA) during surgery is essential for anesthesiologists. Since the effect of anesthetic drugs is on the central nervous system, brain signals such as Electroencephalogram (EEG) can be used for DOA estimation. Anesthesia can interfere among brain regions, so the relationship among different areas can be a key factor in the anesthetic process...
متن کاملA comparison of patient state index and bispectral index values during the perioperative period.
UNLABELLED The patient state index (PSI), a quantitative electroencephalographic index, has been recently introduced into clinical practice as a monitor for assessing consciousness during sedation and general anesthesia. We designed this observational study to compare the sensitivity and specificity of the PSI with that of the bispectral index (BIS) with respect to their ability to predict the ...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملبررسی میزان آگاهی (awareness) در طی بی هوشی عمومی جهت سزارین در بیمارستان های آموزشی دانشگاه علوم پزشکی مازندران در سال 83-84
Background and purpose: Awareness during general anesthesia is a frightening experience that often causes patients to panic and feel helpless even when there is no pain and no feel of body movement and manipulation by the surgeon. Awareness monitoring is still complicated and controversial. Now a days this is based on electroencephalography data such as the bispectral index (BIS) or spectr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 99 5 شماره
صفحات -
تاریخ انتشار 2004