Finite element analysis of three designs of an implant-supported molar crown.

نویسندگان

  • Allahyar Geramy
  • Steven M Morgano
چکیده

STATEMENT OF PROBLEM The optimal method of implant support for a single mandibular molar crown is controversial because commonly used, threaded, root-form implants developed by Branemark were not originally designed to support individual crowns. PURPOSE The purpose of this study was to develop a finite element model of a single mandibular first molar crown supported by (1) a standard 3.75-mm-diameter implant, (2) a 5-mm, wide-diameter implant, and (3) double standard-diameter implants, and to compare the induced displacements as a result of various loading conditions. MATERIAL AND METHODS Three-dimensional finite element models were made to simulate the 3 single-molar implant designs. Each model was analyzed with 2 force magnitudes (35 N and 70 N) and with 2 force directions (vertical and 15 degrees to the vertical axis). Displacements in 3-dimensional space as a result of the simulated loading conditions were evaluated along 3 primary axes, mesiodistal, faciolingual, and superior-inferior. RESULTS Mesiodistal and buccolingual displacements for the crown supported by the 5-mm-diameter implant were reduced by approximately 50% compared with the crown supported by the 3.75-mm implant when the crowns were loaded at the distobuccal cusp tip or the distal marginal ridge. The double-implant design recorded the least mesiodistal displacement with off-center loading of the crown. CONCLUSION When the crown was loaded off-center, the double-implant design produced substantially less displacement when compared with either of the single-implant designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Three-dimensional finite element analysis of implant-supported crown in fibula bone model

PURPOSE The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis. MATERIALS AND METHODS Two three-dimensional finite element models were created to analyze biomechanical behaviors of implant-supported crowns placed in intact mandible and fibula model....

متن کامل

The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis.

PURPOSE The purpose of this study was to determine the amount and localization of functional stresses in implants placed in two different bone types (type 3 and type 4) with three different crown heights in the atrophic posterior maxilla using finite element analysis. MATERIALS AND METHODS A three-dimensional finite element model of the posterior maxilla was created from a computerized tomogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 92 5  شماره 

صفحات  -

تاریخ انتشار 2004