Effects of thermocouple electrical insulation on the measurement ofᅡᅠsurface temperature

نویسندگان

  • Ahmed A.Y. AlWaaly
  • Manosh C. Paul
  • Phillip S. Dobson
چکیده

Analytical, numerical and experimental analyses have been performed to investigate the effects of thermocouple wire electrical insulation on the temperature measurement of a reference surface. Two diameters of type K thermocouple, 80 mm and 200 mm, with different exposed wire lengths (0 mm, 5 mm, 10 mm, 15 mm and 20 mm) were used to measure various surface temperatures (4 C, 8 C, 15 C, 25 C and 35 C). Measurements were made with the thermocouple in direct contact with the surface, with wires extending vertically and exposed to natural convection. Analytical results of the thermocouple wire with insulation confirm that there is no specific value for the critical radius and the rate of heat flux around the thermocouple wire continuously increases with the wire diameter evenwhen this is larger than the critical radius. Numerical simulation using COMSOL Multiphysics software also confirms that there is negligible thermal effect from the electrical insulation. Moreover, the experimental results agree well with those obtained by both the analytical and numerical methods and further confirm that the diameter of the thermocouple has an impact on the temperature measurement. © 2015 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Effects of the current used on determining a critical temperature by electrical resistivity measurements in dental alloys.

The electrical resistivity measurement to determine a critical temperature (Tc) in a stoichiometric CuAu alloy is discussed on the dependence of the current used. The temperature was measured on two ways: With the thermocouple connected to the specimen by spot-welding, and with them separated. In the latter case, the greater the current, the lower the apparent Tc because of the generation of Jo...

متن کامل

Whispering-gallery mode composite sensors for on-chip dynamic temperature monitoring

Whispering-gallery mode temperature microsensors have been demonstrated to have extremely high accuracy. Previous experiments have been limited to indirect sensor heating by externally heating the local environment. In this paper, we coated PDMS films directly onto an electrical resistive wire as sensors, allowing on-chip dynamic temperature measurement. The effects of sensor size are discussed...

متن کامل

An Approach to Thermocouple Measurements That Reduces Uncertainties in High-Temperature Environments

Obtaining accurate temperature measurements with thermocouples in flame environments is challenging due to the effects of radiative heat losses, as these losses are difficult to quantify. Efforts to minimize radiative losses by, for example, suction pyrometry often result in a significant sacrifice in spatial resolution. In this work, a new experimental methodology is presented that both minimi...

متن کامل

Study by simulation the influence of temperature on the formation of space charge in the dielectric multilayer Under DC Electric stress

Multidielectric polyethylene is a material that is generally employed as insulation for  the HVDC isolations. In this paper, the influence of temperature on space charge dynamics has been studied, low-density polyethylene (LDPE) and Fluorinated Ethylene Propylene (FEP) sandwiched between two electrodes were subjected to voltage application of 5kV (14.3 kV/mm) for extended duration of time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015