Investigation of Balance Function Using Dynamic Posturography under Electrical-Acoustic Stimulation in Cochlear Implant Recipients

نویسندگان

  • B. Schwab
  • M. Durisin
  • G. Kontorinis
چکیده

Introduction. The purpose of the present study is to investigate the effect of electrical-acoustic stimulation on vestibular function in CI patients by using the EquiTest and to help answer the question of whether electrically stimulating the inner ear using a cochlear implant influences the balance system in any way. Material and Methods. A test population (n = 50) was selected at random from among the cochlear implant recipients. Dynamic posturography (using the EquiTest) was performed with the device switched off an switched on. Results. In summary, it can be said that an activated cochlear implant affects the function of the vestibular system and may, to an extent, even lead to a stabilization of balance function under the static conditions of dynamic posturography, but nevertheless also to a significant destabilization. Significant improvements in vestibular function were seen mainly in equilibrium scores under conditions 4 and 5, the composite equilibrium score, and the vestibular components as revealed by sensory analysis. Conclusions. Only under the static conditions are significantly poorer scores achieved when stimulation is applied. It may be that the explanation for any symptoms of dizziness lies precisely in the fact that they occur in supposedly noncritical situations, since, when the cochlear implant makes increased demands on the balance system, induced disturbances can be centrally suppressed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of Using Electrocochleography for Objective Estimation of Electro-Acoustic Interactions in Cochlear Implant Recipients with Residual Hearing

Although cochlear implants (CI) traditionally have been used to treat individuals with bilateral profound sensorineural hearing loss, a recent trend is to implant individuals with residual low-frequency hearing. Patients who retain some residual acoustic hearing after surgery often can benefit from electro-acoustic stimulation (EAS) technologies, which combine conventional acoustic amplificatio...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

Neurophysiology of cochlear implant users II: comparison among speech perception, dynamic range, and physiological measures.

OBJECTIVE The overall objective of this study was to relate electrically evoked potentials recorded from different levels of the auditory pathway with behavioral measures obtained from adult cochlear implant subjects. The hypothesis was that adult recipients of cochlear implants who have open-set speech perception and those recipients with no open-set speech perception would differ in their neu...

متن کامل

Electroacoustic Stimulation: Now and into the Future

Cochlear implants have provided hearing to hundreds of thousands of profoundly deaf people around the world. Recently, the eligibility criteria for cochlear implantation have been relaxed to include individuals who have some useful residual hearing. These recipients receive inputs from both electric and acoustic stimulation (EAS). Implant recipients who can combine these hearing modalities demo...

متن کامل

On the Relationship Between Noise and Speech Recognition in Cochlear Implant Subjects: A Theoretical and Psychophysical Study

One factor that may impede speech recognition by cochlear implant subjects is that electrically stimulated nerves respond with a much higher level of synchrony than what is normally observed in acoustically stimulated nerves. Thus, the response patterns “seen” at higher processing centers are substantially different from those generated under normal acoustic stimulation. These differences may f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010