A nonfluoroscopic approach for electrophysiology and catheter ablation procedures using a three-dimensional navigation system.

نویسنده

  • Volkan Tuzcu
چکیده

BACKGROUND Three-dimensional (3D) electroanatomical navigation systems decrease the fluoroscopy time of electrophysiology and ablation procedures. The aim of this study was to assess the safety and efficacy of a complete nonfluoroscopic approach for electrophysiologic studies and right-sided catheter ablations for supraventricular tachycardia in patients with normal cardiac anatomy using a 3D, surface electrode-based navigation system (NavX, St. Jude Medical, St. Paul, MN, USA). METHODS AND RESULTS Electrophysiologic studies were performed in 26 consecutive cases (12.7 +/- 7.5 years) using NavX without fluoroscopy. The procedure time was 98.7 +/- 49.7 minutes. Nonfluoroscopic catheter ablations were performed in 24 of 28 consecutive patients. Cryoablation was used in 23 of 24. The procedure time was 193.5 +/- 80 minutes. The coronary sinus access was obtained in 32.1 +/- 12 (range: 15-60) seconds. No complications occurred. All patients (n = 19) who underwent cryoablation for right-sided arrhythmia substrates with conventional fluoroscopic guidance in addition to NavX were used as a control group (10.1 +/- 5.2 years). Catheter ablation success rate of the control group (16/19, 84%) was not significantly different compared to the patients who underwent ablation without fluoroscopy (22/24, 92%). The procedure time was also not significantly different between the two groups (P = NS). CONCLUSION This study demonstrates that nonfluoroscopic electrophysiologic studies and right-sided catheter ablations for supraventricular tachycardia can be safely and effectively performed in the majority of patients with normal cardiac anatomy using NavX. Further studies will be necessary in order to establish the potential utility of NavX in eliminating or decreasing radiation exposure for other electrophysiology procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiofrequency ablation of accessory pathways in children and congenital heart disease patients: impact of a nonfluoroscopic navigation system.

BACKGROUND We sought to assess the impact of routine use of a nonfluoroscopic navigation system in the procedural aspects of radiofrequency ablation of accessory pathways (APs) in pediatric and congenital heart disease (CHD) patients and the reduction of fluoroscopy in different pathway locations. METHODS This was a retrospective review of 192 patients, divided in two groups: group A (76 pati...

متن کامل

Nonfluoroscopic catheter navigation for radiofrequency catheter ablation of supraventricular tachycardia in children.

BACKGROUND Radiofrequency catheter ablation (RCA) of supraventricular tachycardia (SVT) in children is highly successful but requires exposure to radiation. Nonfluoroscopic mapping systems may significantly reduce fluoroscopy time. METHODS Forty consecutive pediatric patients who underwent RCA for accessory pathways (AP) or AV nodal reentrant tachycardia (AVNRT) with use of a nonfluoroscopic ...

متن کامل

Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

BACKGROUND We describe a novel fluoroscopy coregistered, 4-dimensional catheter tracking technology (MediGuide Technology [MGT]) used for treatment of patients with atrial fibrillation. The aim of the study was to investigate (1) the feasibility of nonfluoroscopic catheter manipulation within dynamic left atrial chamber models; (2) the integration of the technology into an established electroan...

متن کامل

Ablation of typical atrial flutter using a novel non-fluoroscopic

1 Interv. Cardiol. (2014) 6(2), 00–00 ISSN 1755-5302 Summary Typical atrial flutter is characterized by a stable macro-reentrant circuit around the tricuspid annulus with the cavotricuspid isthmus serving as the critical zone of slow conduction. Catheter ablation targeting this isthmus provides a curative and safe treatment option for the vast majority of patients with atrial flutter. The conve...

متن کامل

Nonfluoroscopic catheter visualization in atrial fibrillation ablation: experience from 375 consecutive procedures.

BACKGROUND A technological platform (MediGuide) has been recently introduced for nonfluoroscopic catheter tracking. No data on the safety of this technology are yet available in a large cohort of patients. METHODS AND RESULTS Data from a prospective ablation registry were analyzed. All patients undergoing atrial fibrillation ablation procedures supported by nonfluoroscopic catheter visualizat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2007