Airway management by first responders when using a bag-valve device and two oxygen-driven resuscitators in 104 patients.

نویسندگان

  • G J Noordergraaf
  • P J van Dun
  • B P Kramer
  • M P Schors
  • H P Hornman
  • W de Jong
  • A Noordergraaf
چکیده

BACKGROUND AND OBJECTIVE To evaluate the capability of first responders to ensure an airway and ventilate the lungs of a patient employing a bag-valve device and two oxygen-driven resuscitators. METHODS Prospective, controlled, blinded, single-centre clinical trial using a bag-valve device and one of two FR-300 devices, with 20 cmH2O working pressure, flows of 24 and 30 L min(-1). One-hundred-and-four patients were analysed. Induction of anaesthesia was followed by ventilation of the lungs with a bag-valve device and an Oxylator (CPR Medical Devices Corp., Markham, Ontario, Canada) in manual and automatic modes. Each series was repeated twice by a fireman first responder using a hand-held mask to seal the airway, once under anaesthesia and then again under anaesthesia with muscle relaxation. RESULTS Patients' mean age 49 +/- 17 yr; 47% male, 48-132 kg. Only 29% had optimal facial and airway physiognomy. Airway management was significantly poorer when the bag-valve device was used than with either Oxylator mode (P < 0.0001); 23% of cases were not manageable with the bag-valve device. Gastric insufflation was markedly less with the Oxylator (P < 0.02). CONCLUSIONS The use of an oxygen-driven device improves the ability of first responders to secure an airway and reduce gastric insufflation, even when distracted. Oxylators perform significantly better (P < 0.0001) than the bag-valve device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can first responders achieve and maintain normocapnia when sequentially ventilating with a bag-valve device and two oxygen-driven resuscitators? A controlled clinical trial in 104 patients.

BACKGROUND AND OBJECTIVE To evaluate the capability of first responders to achieve and maintain normal ventilation of the lungs of victims employing a bag-valve device and two oxygen-driven resuscitators. METHODS Prospective, controlled, blinded, single-centre clinical trial using a bag-valve device and one of two FR-300 devices, with 20 cmH2O working pressure, and flows of either 24 or 30 L ...

متن کامل

Evaluation of 16 adult disposable manual resuscitators.

INTRODUCTION Disposable manual resuscitators are commonly used to ventilate patients during cardiopulmonary resuscitation, suctioning, and intrahospital transport, and their clinical performance is critical. METHODS We bench-tested 16 adult disposable manual resuscitators from 9 different manufacturers. We performed a series of tests and made observations using testing industry standards as a...

متن کامل

Comparison of the FiO2 delivered by seven models of the self-inflating bag-mask system.

BACKGROUND AND OBJECTIVES Since resuscitators with self-inflating bag-mask systems manufactured and/or commercialized in Brazil are widely available and used in health services, both out- and intra-hospitals, the objective of this study was to determine the O2 fractions delivered by seven resuscitators receiving different O2 flows. METHODS Seven resuscitators with self-inflating bag-mask syst...

متن کامل

Efficacy of Nasal Cannula Oxygen as a Preoxygenation Adjunct in Emergency Airway Management.

STUDY OBJECTIVE Although preoxygenation for emergency airway management is usually performed with nonrebreather face masks or bag-valve-mask devices, some clinicians also deliver supplemental high-flow oxygen by nasal cannula. We aim to measure the efficacy of supplemental nasal cannula oxygen delivery to conventional bag-valve-mask and nonrebreather face mask preoxygenation both with and witho...

متن کامل

Anesthesia in prehospital emergencies and in the emergency department.

PURPOSE OF REVIEW Recently, notable progress has been made in the field of anesthesia drugs and airway management. RECENT FINDINGS Anesthesia in prehospital emergencies and in the emergency department is reviewed and guidelines are discussed. SUMMARY Preoxygenation should be performed with high-flow oxygen delivered through a tight-fitting face mask with a reservoir. Ketamine may be the ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2004