Validation of a Novel Device to Measure and Provide Feedback on Sedentary Behavior

نویسندگان

  • JASON M. R. GILL
  • NABEHA S. A. HAWARI
  • DOUGLAS J. MAXWELL
  • DAVID LOUDEN
  • NIKOS MOURSELAS
  • CHRISTOPHER BUNN
  • CINDY M. GRAY
  • HIDDE P. VAN DER PLOEG
  • KATE HUNT
  • ANNE MARTIN
  • SALLY WYKE
  • NANETTE MUTRIE
چکیده

PURPOSE Pedometers, which enable self-monitoring of step counts, are effective in facilitating increases in physical activity. Similar devices which provide real-time feedback on sedentary (sitting) behavior are limited. This study aimed to develop and validate a novel device-the SitFIT-which could accurately measure and provide feedback on sedentary behavior and physical activity. METHODS The SitFIT is a triaxial accelerometer, developed by PAL Technologies, which is worn in the front trouser pocket. This enables tracking of thigh inclination and therefore differentiation between sitting and upright postures, as well as tracking of step count. It has a display to provide user feedback. To determine the validity of the SitFIT for measuring sedentary behavior and step counts, 21 men, age 30 to 65 yr, with body mass index 26.6 ± 3.9 kg·m wore a SitFIT in a front trouser pocket and an activPAL accelerometer attached to their thigh for up to 7 d. Outputs from the SitFIT were compared with the activPAL, which was assumed to provide criterion standard measurements of sitting and step counts. RESULTS Mean step counts were approximately 4% lower with the SitFIT than activPAL, with correlation between the two methods being very high (r = 0.98) and no obvious bias from the line of equality (regression line, y = 1.0035x + 418.35). Mean sedentary time was approximately 5% higher with the SitFIT than activPAL, correlation between methods was high (r = 0.84), and the equation of the regression line was close to the line of equality (y = 0.8728x + 38.445). CONCLUSIONS The SitFIT has excellent validity for measurement of free-living step counts and sedentary time and therefore addresses a clear need for a device that can be used as a tool to provide feedback on sedentary behavior to facilitate behavior change.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Believable Visual Feedback in Motor Learning Using Occlusion-based Clipping in Video Mapping

Gait rehabilitation systems provide patients with guidance and feedback that assist them to better perform the rehabilitation tasks. Real-time feedback can guide users to correct their movements. Research has shown that the quality of feedback is crucial to enhance motor learning in physical rehabilitation. Common feedback systems based on virtual reality present interactive feedback in a monit...

متن کامل

Bandwidth and Delay Optimization by Integrating of Software Trust Estimator with Multi-User Cloud Resource Competence

Trust Establishment is one of the significant resources to enhance the scalability and reliability of resources in the cloud environment. To establish a novel trust model on SaaS (Software as a Service) cloud resources and to optimize the resource utilization of multiple user requests, an integrated software trust estimator with multi-user resource competence (IST-MRC) optimization mechanism is...

متن کامل

Development and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance

Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...

متن کامل

An Empirical Comparison of Distance Measures for Multivariate Time Series Clustering

Multivariate time series (MTS) data are ubiquitous in science and daily life, and how to measure their similarity is a core part of MTS analyzing process. Many of the research efforts in this context have focused on proposing novel similarity measures for the underlying data. However, with the countless techniques to estimate similarity between MTS, this field suffers from a lack of comparative...

متن کامل

Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2018