Comparison of optic disc margin identified by color disc photography and high-speed ultrahigh-resolution optical coherence tomography.

نویسندگان

  • Anita Manassakorn
  • Hiroshi Ishikawa
  • Jong S Kim
  • Gadi Wollstein
  • Richard A Bilonick
  • Larry Kagemann
  • Michelle L Gabriele
  • Kyung Rim Sung
  • Tarkan Mumcuoglu
  • Jay S Duker
  • James G Fujimoto
  • Joel S Schuman
چکیده

OBJECTIVE To determine the correspondence between optic disc margins evaluated using disc photography (DP) and optical coherence tomography (OCT). METHODS From May 1, 2005, through November 10, 2005, 17 healthy volunteers (17 eyes) had raster scans (180 frames, 501 samplings per frame) centered on the optic disc taken with stereo-optic DP and high-speed ultrahigh-resolution OCT (hsUHR-OCT). Two image outputs were derived from the hsUHR-OCT data set: an en face hsUHR-OCT fundus image and a set of 180 frames of cross-sectional images. Three ophthalmologists independently and in a masked, randomized fashion marked the disc margin on the DP, hsUHR-OCT fundus, and cross-sectional images using custom software. Disc size (area and horizontal and vertical diameters) and location of the geometric disc center were compared among the 3 types of images. RESULTS The hsUHR-OCT fundus image definition showed a significantly smaller disc size than the DP definition (P <.001, mixed-effects analysis). The hsUHR-OCT cross-sectional image definition showed a significantly larger disc size than the DP definition (P <.001). The geometric disc center location was similar among the 3 types of images except for the y-coordinate, which was significantly smaller in the hsUHR-OCT fundus images than in the DP images. CONCLUSION The optic disc margin as defined by hsUHR-OCT was significantly different than the margin defined by DP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.

PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...

متن کامل

Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.

PURPOSE To determine the retinal nerve fiber layer (RNFL) thickness profile in the peripapillary region of healthy eyes. METHODS Three-dimensional, Fourier/spectral domain optical coherence tomography (OCT) data were obtained as raster scan data (512 x 180 axial scans in a 6 x 6-mm region centered on the optic nerve head [ONH]) with high-speed, ultrahigh-resolution OCT (hsUHR-OCT) from 12 hea...

متن کامل

Comparison Of Results Of Optic Disc Analysis Using Stereoscopic Biomicroscopy, Stereo Fundus Photography and Optical Coherence Tomography

Aim – To compare the results of optic disc analysis using optical coherence tomography, fundus photography and stereoscopic biomicroscopy. Materials & Methods – A comparative, observational case series and interobserver variability study in which 2 groups of patients were analysed by all the 3 methods. One group had primary open angle glaucoma patients and the other group were patients undergoi...

متن کامل

Correlation between Optic Nerve Parameters Obtained Using 3D Nonmydriatic Retinal Camera and Optical Coherence Tomography: Interobserver Agreement on the Disc Damage Likelihood Scale

Purpose. To compare stereometric parameters obtained by three-dimensional (3D) optic disc photography and optical coherence tomography (OCT) and assess interobserver agreement on the disc damage likelihood scale (DDLS). Methods. This retrospective study included 190 eyes from 190 patients classified as normal, glaucoma suspect, or glaucomatous. Residents at different levels of training complete...

متن کامل

Reproducibility of Perfusion Parameters of Optic Disc and Macula in Rhesus Monkeys by Optical Coherence Tomography Angiography

BACKGROUND Optical coherence tomography (OCT) angiography is a novel technique by which we can detect the local perfusion of fundus directly. The aim of this study was to evaluate the reproducibility of optic disc and macular flow perfusion parameters in rhesus monkeys using OCT angiography. METHODS Eighteen healthy monkeys (18 eyes) were subjected to optic disc and macula flow index measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 126 1  شماره 

صفحات  -

تاریخ انتشار 2008